Reporter gene assay for detection of biological activity of human growth hormone / 中国生物制品学杂志
Chinese Journal of Biologicals ; (12): 594-598, 2023.
Article Dans Chinois | WPRIM | ID: wpr-996376
ABSTRACT
@#Objective To develop and verify a reporter gene assay(RGA) for the detection of biological activity of human growth hormone(hGH).Methods The biological activity of hGH was evaluated by the expression of luciferase(Luc)activated by hGH binding to hGH receptor(hGHR) on HEK293/GH-Luc cell membrane.The developed detection conditions were as followsthe initial concentration of sample was 1 μg/mL;the cell inoculation amount was(2.45~2.66) × 10~4 cells/well;the sample was of 3-fold serial dilution,with a total of 8 dilutions and the incubation time was 18~24 h.The relative biological activity of the sample was calculated by measuring Luc intensity and comparing it with the national standard by four-parameter fitting.The developed method was verified for specificity,repeatability,intermediate precision,relative accuracy,linear range and durability.Results The excipient components in product and the serum components in culture medium showed no effect on the activity detection results;The geometric coefficient of variation(GCV) of relative titer of one batch of samples in six repeated detections was 6.794%,much lower than 20%.The relative titer GCV detected by two experimenters in different batches of samples at different times were both lower than 20%;The relative deviations of the relative titer determination values of samples at different concentrations were within ±12%,the slope of linear regression equation was 0.982,the linear range was 0.6~1.6 μg/mL,and the coefficient of determination(R~2) was 0.997;The GCV of three batches of stock solutions and one batch of finished products were 4.758%,4.430%,7.294% and 2.771% respectively under the conditions of different cell generation,cell density and sampling location,all of which were less than 20%.Conclusion The developed RGA showed good specificity,repeatability,intermediate precision,relative accuracy,linear range and durability,which met the application requirements and was expected to replace the traditional in vivo biological activity detection methods for the activity evaluation and quality control of hGH.

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Journal of Biologicals Année: 2023 Type: Article

Documents relatifs à ce sujet

MEDLINE

...
LILACS

LIS

Texte intégral: Disponible Indice: WPRIM (Pacifique occidental) langue: Chinois Texte intégral: Chinese Journal of Biologicals Année: 2023 Type: Article