Estudio Descriptivo: Dosis Efectiva de Radiación en Angiotomografías Coronarias Multidetector de Enero del 2013 a Diciembre del 2015 en el Hospital de Especialidades José Carrasco Arteaga
Ortega Díaz, Carlos Ismael; Vintimilla Garate, Juan; Quizhpe Rivera, Arturo Ricardo; Moreira Vera, Winston Xavier; Garcia Zambrano, María José; Coronel Cardenas, Byron Rafael; Criollo Esquivel, Priscila Raquel; Salazar Alvarado, Xavier Miguel.
  • Ortega Díaz, Carlos Ismael; Hospital de Especialidades José Carrasco Arteaga. Unidad de Cardiología. Cuenca. EC
  • Vintimilla Garate, Juan; Hospital de Especialidades José Carrasco Arteaga. Unidad de Cardiología. Cuenca. EC
  • Quizhpe Rivera, Arturo Ricardo; Hospital de Especialidades José Carrasco Arteaga. Unidad de Cardiología. Cuenca. EC
  • Moreira Vera, Winston Xavier; Hospital de Especialidades José Carrasco Arteaga. Unidad de Cardiología. Cuenca. EC
  • Garcia Zambrano, María José; Hospital de Especialidades José Carrasco Arteaga. Unidad de Cardiología. Cuenca. EC
  • Coronel Cardenas, Byron Rafael; Hospital de Especialidades José Carrasco Arteaga. Unidad de Cardiología. Cuenca. EC
  • Criollo Esquivel, Priscila Raquel; Centro de Salud San Carlos. Naranjal. EC
  • Salazar Alvarado, Xavier Miguel; Hospital Monte Sinaí. Cuenca. EC
Rev. méd. Hosp. José Carrasco Arteaga ; 9(2): 134-138, Julio 2017.
Artigo em Espanhol | LILACS | ID: biblio-1009385
RESUMEN

INTRODUCCIÓN:

La coronariografia convencional sigue siendo el patrón de referencia para cuantificar y guiar el tratamiento en la enfermedad coronaria sin embargo con la introducción de la angiotomografía coronaria multidetector en la valoración de placas ateromatosas coronarias y con esto la exposición a la radiación ha permanecido como área de constante preocupación. En la práctica diaria se recomienda basarse en lo que se conoce como As Low As Reasonably Achievable que significa optimizar la radiación sin perjuicio de la calidad del estudio.

MÉTODOS:

Se trata de un estudio descriptivo retrospectivo en el Hospital de Especialidades José Carrasco Arteaga de Cuenca ­ Ecuador, durante el periodo de tiempo comprendido entre el 01 enero del 2013 y 31 diciembre del 2015. Para este estudio se incluyeron todos los pacientes a quienes se les realizó angiotomografía coronaria multidetector, se recolectaron los datos clínicos y la dosis efectiva de radiación de cada paciente.

RESULTADOS:

La edad promedio fue de 63.2 años. Con una probabilidad pre-test intermedia-baja para enfermedad coronaria en más del 94 % de los pacientes, de los cuales el promedio de dosis de radiación efectiva en angiotomografía coronaria multidetector es de 13.0276 mSv (0.9002 ­ 20.657).

CONCLUSION:

Se trata del primer estudio en el medio donde investiga la dosis de radiación utilizada en angiotomografía coronaria multidetector permitiendo conocer la media de dosis efectiva y así optimizar la misma mediante técnicas de reducción.
ABSTRACT

INTRODUCTION:

The conventional coronography continues to be the standard used to quantify and manage the treatment of coronary disease. However, with the introduction of the multidetector coronary angiothomography in the evaluation of coronary atheromatous plaque, the exposure to radiation has continued to be an area of constant concern. It is recommended that in daily practice the As Low as Reasonably Achievable guidelines be used, which means optimizing the amount of radiation without affecting the quality of the study.

METHOD:

This a descriptive retrospective study that took place at the José Carrasco Arteaga Specialties Hospital in Cuenca ­ Ecuador, covering the time period between January 1, 2013 from December 31, 2015. The clinical data and effective dose of radiation of each patient who underwent a multidetector coronary angiothomography during this time span were included in the study.

RESULTS:

The average age was 63.2 years, with a low to intermediate pre-test probability of coronary disease in over 94 % of the patients. The average dose of effective radiation in multidetector coronary angiothomography was of 13.0276 mSv (0.9002-20.657).

CONCLUSIONS:

This is the first study in our area where the dose of radiation used in multidetector coronary angiothomography has been investigated, making it possible to identify the effective half dose, in this way optimizing the same through the use of reduction techniques.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Doença das Coronárias / Angiografia por Tomografia Computadorizada Tipo de estudo: Estudo de etiologia / Guia de Prática Clínica / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Humanos Idioma: Espanhol Revista: Rev. méd. Hosp. José Carrasco Arteaga Assunto da revista: Medicina / Sa£de P£blica Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Brasil / Equador Instituição/País de afiliação: Centro de Salud San Carlos/EC / Hospital Monte Sinaí/EC / Hospital de Especialidades José Carrasco Arteaga/EC

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Doença das Coronárias / Angiografia por Tomografia Computadorizada Tipo de estudo: Estudo de etiologia / Guia de Prática Clínica / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Humanos Idioma: Espanhol Revista: Rev. méd. Hosp. José Carrasco Arteaga Assunto da revista: Medicina / Sa£de P£blica Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Brasil / Equador Instituição/País de afiliação: Centro de Salud San Carlos/EC / Hospital Monte Sinaí/EC / Hospital de Especialidades José Carrasco Arteaga/EC