The predictive effects of clinical hematological changes on saphenous graft patency after coronary artery surgery
Íyigün, Taner; Kyaruzi, Mugisha Markior; Timur, Baris; Satilmisoglu, Muhammed Hulusi; Iyigün, Müzeyyen; Kaya, Mehmet.
  • Íyigün, Taner; Cardiovascular Surgery Training and Research Hospital. Department of Cardiovascular Surgery. Istanbul. TR
  • Kyaruzi, Mugisha Markior; Cardiovascular Surgery Training and Research Hospital. Department of Cardiovascular Surgery. Istanbul. TR
  • Timur, Baris; Cardiovascular Surgery Training and Research Hospital. Department of Cardiovascular Surgery. Istanbul. TR
  • Satilmisoglu, Muhammed Hulusi; Cardiovascular Surgery Training and Research Hospital. Department of Cardiology. Istanbul. TR
  • Iyigün, Müzeyyen; Acıbadem University. Department of Anesthesiology and Reanimation. Istanbul. TR
  • Kaya, Mehmet; Cardiovascular Surgery Training and Research Hospital. Department of Cardiovascular Surgery. Istanbul. TR
Rev. bras. cir. cardiovasc ; 34(3): 297-304, Jun. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1013476
ABSTRACT
Abstract

Objectives:

To investigate the association between clinical hematologic parameters and saphenous vein graft failure after on-pump coronary artery bypass surgery.

Methods:

A total of 1950 consecutive patients underwent isolated on-pump coronary artery surgery between November 2010 and February 2013. Of these, 284 patients met our inclusion criteria; their preoperative clinical hematological parameters were retrospectively obtained for this cohort study. And of them, 109 patients underwent conventional coronary angiography after graft failure was revealed by coronary computed tomography angiography. The primary endpoint was to catch at least one saphenous vein graft stenosis or occlusion following the coronary angiogram. We then analyzed risk factors for graft failure. In sequential or T grafts, each segment was analyzed as a separate graft.

Results:

In logistic regression analysis, older age, platelet distribution width, and diabetes mellitus were identified as independent predictors of saphenous vein graft failure (P<0.). In contrast, preserved ejection fraction value favored graft patency (P<0.001).

Conclusion:

Increased platelet distribution width is easily measurable and can be used as a simple and valuable marker in the prediction of saphenous vein graft failure.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Veia Safena / Plaquetas / Grau de Desobstrução Vascular / Ponte de Artéria Coronária Tipo de estudo: Estudo de etiologia / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Inglês Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2019 Tipo de documento: Artigo País de afiliação: Turquia Instituição/País de afiliação: Ac&#305;badem University/TR / Cardiovascular Surgery Training and Research Hospital/TR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Veia Safena / Plaquetas / Grau de Desobstrução Vascular / Ponte de Artéria Coronária Tipo de estudo: Estudo de etiologia / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Inglês Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2019 Tipo de documento: Artigo País de afiliação: Turquia Instituição/País de afiliação: Ac&#305;badem University/TR / Cardiovascular Surgery Training and Research Hospital/TR