RESUMEN
RESUMEN Introducción:
La Ley de Zipf-Mandelbrot permitió el desarrollo de una metodología que realiza distinciones cuantitativas entre dinámicas cardíacas agudas y normales, de forma objetiva y reproducible.Objetivo:
Confirmar la capacidad diagnóstica y utilidad clínica de un software que automatiza una metodología basada en la Ley de Zipf-Mandelbrot, que realiza diagnósticos objetivos de la dinámica cardíaca. Material yMétodos:
Se realizó un estudio ciego con 80 registros Holter, 20 normales y 60 con hallazgos patológicos. El software organizó de manera jerárquica las frecuencias cardíacas mediante las frecuencias de aparición en rangos de 15 lat/min, linealizó los datos y obtuvo la dimensión fractal estadística, lo cual permitió la realización del análisis de complejidad.Resultados:
La dimensión fractal estadística de los registros Holter normales se halló entre 0,720 y 0,913, y exhibió valores entre 0,454 y 0,665 en los registros Holter anormales. Se encontró un coeficiente Kappa de 1, y valores de especificidad y sensibilidad de 100%.Conclusiones:
Se confirmó la utilidad clínica del software que automatiza la metodología fundamentada en La ley de Zipf-Mandelbrot, el cual permitió evaluar el comportamiento de los sistemas cardíacos normales y agudos.ABSTRACT
ABSTRACT Introduction:
The Zipf-Mandelbrot law allowed the development of a methodology that makes quantitative distinctions between acute and normal cardiac dynamics in an objective and reproducible way.Objective:
To confirm the diagnostic capacity and clinical utility of the software that automates a methodology based on the Zipf-Mandelbrot law that performs objective diagnoses of the cardiac dynamics. Material andMethods:
A blind study was performed with 80 Holter records, 20 normal and 60 with pathological findings. The software organized heart rates in a hierarchical way through their frequencies of occurrence in ranges of 15 beats per min, linearized data, and obtained statistical fractal dimension which allowed the realization of the complexity analysis.Results:
The statistical fractal dimension of the normal Holter records was found between 0,720 and 0,913, and exhibited values between 0,454 and 0,665 in the abnormal Holter records. A Kappa coefficient of 1, and specificity and sensitivity values of 100% were found. ConclusionsMethods:
The clinical utility of the Software that automates the methodology based on the Zipf-Mandelbrot law was confirmed, which allowed to evaluate the behavior of normal and acute cardiac systems.
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Tipo de estudo:
Estudo diagnóstico
Idioma:
Espanhol
Revista:
Rev. habanera cienc. méd
Assunto da revista:
Medicina
Ano de publicação:
2019
Tipo de documento:
Artigo
País de afiliação:
Colômbia
Instituição/País de afiliação:
Centro de Investigaciones Clínica del Country/CO
/
Institución Universitaria Politécnico Grancolombiano/CO
Similares
MEDLINE
...
LILACS
LIS