Elaboração, validação e reprodutibilidade de um questionário de frequência alimentar para hipertensos e/ou diabéticos / Development, validation and reproducibility of a food frequency questionnaire focused on adult hypertensive and/or diabetic individuals
Demetra (Rio J.)
; 15(1): e44161, jan.- mar.2020. tab
Article
em En, Pt
| LILACS
| ID: biblio-1099822
Biblioteca responsável:
BR1691.1
RESUMO
Objetivo:
O presente estudo teve por objetivo elaborar e avaliar a validade e a reprodutibilidade de um questionário de frequência alimentar (QFA) para hipertensos e/ou diabéticos do município de Maceió-AL, Brasil.Métodos:
O QFA foi elaborado a partir de 1.603 inquéritos dietéticos recordatórios de 24 h (IDR24H). Para avaliar a validade e a reprodutibilidade do QFA aplicaram-se, em uma amostra de 40 indivíduos, três QFAS e três IDR24H concomitantemente e com intervalo máximo de 45 dias entre as aplicações. A validade foi avaliada por meio dos coeficientes de correlação de Pearson (CCP) ou de Spearman (CCS) entre o QFA 1, 2 e 3, e a média dos 3IDR24H, adotando-se o IDR24H como padrão de referência; e a reprodutibilidade, por meio do coeficiente de correlação intraclasse (CCI) entre os QFAs.Resultados:
Quanto à validade, os CCP ou CCS atingiram os valores recomendados entre 0,4 e 0,7 para energia, macronutrientes, cálcio e sódio para as aplicações 1 e 2 do QFA (validade satisfatória); e para os demais nutrientes, CCP < 0,4. Quanto à reprodutibilidade, todos os nutrientes estudados apresentaram CCI dentro dos valores recomendados, exceto potássio entre QFA1 e QFA3 (CCI = 0,28).Conclusão:
O QFA elaborado e avaliado neste estudo constitui um bom instrumento de avaliação de consumo alimentar para avaliação de energia, macronutrientes, cálcio e sódio para hipertensos e/ou diabéticos, podendo fornecer informações importantes para estudos de epidemiologia nutricional neste público-alvo. (AU)ABSTRACT
Objective:
The aims of the current study are to develop and assess the validity and reproducibility of a food frequency questionnaire (FFQ) focused on hypertensive and/or diabetic individuals living in Maceió City - AL, Brazil.Methods:
The questionnaire was developed based on 1,603 twenty-four-hour recall dietary surveys (24-HDR). Three FFQs and three 24-HDRs were concomitantly applied to a sample of 40 individuals, at maximum interval of 45 days between applications, in order to assess FFQ validity and reproducibility. Validity assessment was based on Pearson's (PCC) or Spearman's (SCC) correlation coefficient between FFQs 1, 2, 3 and the mean of three 24-HDRs (the 24- HDR was used as reference standard). Reproducibility assessment was based on the intraclass correlation coefficient (ICC) among FFQs.Results:
PCCs or SCCs recorded the recommended validity values (from 0.4 and 0.7) for energy, macronutrients, calcium and sodium in FFQs 1 and 2 (satisfactory validity), whereas other nutrients recorded PCC < 0.4. All investigated nutrients presented ICC within the recommended reproducibility values, except for potassium, which recorded ICC equal to 0.28 between FFQs 1 and 3.Conclusion:
The FFQ developed and evaluated in the current study is a good food intake-evaluation instrument to assess energy, macronutrients, calcium and sodium in hypertensive and/or diabetic individuals, since it can provide important information for studies about nutritional epidemiology in this target population. (AU)Palavras-chave
Texto completo:
1
Índice:
LILACS
Assunto principal:
Inquéritos e Questionários
/
Diabetes Mellitus
/
Comportamento Alimentar
/
Hipertensão
Tipo de estudo:
Screening_studies
Limite:
Adult
/
Female
/
Humans
/
Male
Idioma:
En
/
Pt
Revista:
Demetra (Rio J.)
Assunto da revista:
Cincias Humanas
/
Fisiologia
Ano de publicação:
2020
Tipo de documento:
Article