Your browser doesn't support javascript.
loading
Parámetros de calidad de concentrados plaquetarios obtenidos por buffy coat en un hospital general del Perú / Quality parameters of platelet concentrates obtained by buffy coat in a general hospital of Perú
Córdova-Vicerrel, Rocío Del Rosario; Huertas-Talavera, Eric.
  • Córdova-Vicerrel, Rocío Del Rosario; Hospital Regional de Ica. Ica. PE
  • Huertas-Talavera, Eric; Universidad Nacional San Luis Gonzaga. Facultad de Medicina. Ica. PE
Rev. méd. panacea ; 8(3): 96-100, sept.-dic. 2019. graf
Artigo em Espanhol | LIPECS, LILACS | ID: biblio-1122277
RESUMEN

Objetivo:

Verificar si los concentrados plaquetarios obtenidos por buffy coat cumplen con los parámetros de calidad en el banco de sangre de un Hospital General del Perú. Materiales y

métodos:

Se realizó un estudio descriptivo transversal. La población estuvo constituida por los donantes que acudieron al Banco de sangre del Hospital Regional de Ica durante los meses de febrero y marzo del 2017, de donde se obtuvo un tamaño muestral de 67 concentrados plaquetarios que cumplieron con los criterios de inclusión según el PRONAHEBAS, con un nivel de confianza del 95%, proporción esperada del 5% y un error del 5%. Los datos evaluados fueron Inspección visual, presencia de remolino, medición de volumen, medición del potencial de Hidrógeno (pH), recuentos de plaquetas, leucocitos residuales; y a través de cultivos microbiológicos, la contaminación bacteriana, las mismas que fueron llenadas en un Instrumento de evaluación de datos, que luego fueron procesados a través del programa estadístico SPSS vs 22, aplicándoseles después estadística descriptiva con medidas de frecuencia para las variables cualitativas, y medidas de tendencia central para las variables cuantitativas.

Resultados:

El 68% de las muestras evaluadas tuvieron una coloración normal. Sólo el 48% tuvo un aspecto aceptable con swirling demostrando presencia de plaquetas en forma indirecta. La gran mayoría presentó volúmenes inadecuados de plasma sobrepasando el límite superior. EL pH presentó una amplia gama de variación; sólo la quinta parte de ella tuvo una medida óptima con respecto a este ítem. Los recuentos de plaquetas estuvieron por debajo del recuento aceptable (74%). La leucorreducción y la presencia de contaminación bacteriana, fueron las características óptimas en un 100% de la muestra estudiada.

Conclusiones:

La mayoría de parámetros calidad en el banco de sangre del Hospital Regional de Ica no cumplieron con los requisitos establecidos según estándares establecidos, por lo que el presente estudio sirve de base para continuar con otras investigaciones donde se identifique la falla probable en el procedimiento o patología de nuestros donantes que redunde en una inadecuada obtención de concentrados plaquetarios por el método de buffy coat. (AU)
ABSTRACT

Objective:

To verify if the platelet concentrates obtained by buffy coat comply with the quality parameters in the blood bank of a General Hospital of Peru. Materials and

methods:

A cross-sectional descriptive study was carried out. The population was made up of donors who went to the Blood Bank of the Ica Regional Hospital during the months of February and March 2017, where a sample size of 67 platelet concentrates was obtained that met the inclusion criteria according to PRONAHEBAS, with a confidence level of 95%, expected proportion of 5% and an error of 5%. The data evaluated were visual inspection, swirling presence, volume measurement, hydrogen potential measurement (pH), platelet counts, residual leukocytes; and through microbiological cultures, the bacterial contamination, the same ones that were filled in a Data Evaluation Instrument, which were then processed through the statistical program SPSS vs 22, then applied descriptive statistics with frequency measures for the qualitative variables, and measures of central tendency for quantitative variables.

Results:

68% of the samples evaluated had a normal coloration. Only 48% had an acceptable appearance with swirling demonstrating the presence of platelets indirectly. The vast majority presented inadequate volumes of plasma exceeding the upper limit. The pH presented a wide range of variation; Only one fifth of it had an optimal measure with respect to this item. Platelet counts were below the acceptable count (74%). Leukoreduction and the presence of bacterial contamination were the optimal characteristics in 100% of the sample studied.

Conclusions:

The majority of quality parameters in the blood bank of the Regional Hospital of Ica did not comply the requirements established according to established standards, so the present study serves as a basis to continue with other investigations where the probable failure in the procedure is identified or pathology of our donors that results in an inadequate obtaining of platelet concentrates by the method of buffy coat. (AU)
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Plasma Rico em Plaquetas / Buffy Coat Tipo de estudo: Guia de Prática Clínica / Estudo observacional / Estudo de prevalência / Estudo prognóstico / Pesquisa qualitativa / Fatores de risco Limite: Humanos País/Região como assunto: América do Sul / Peru Idioma: Espanhol Revista: Rev. méd. panacea Ano de publicação: 2019 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Regional de Ica/PE / Universidad Nacional San Luis Gonzaga/PE

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Plasma Rico em Plaquetas / Buffy Coat Tipo de estudo: Guia de Prática Clínica / Estudo observacional / Estudo de prevalência / Estudo prognóstico / Pesquisa qualitativa / Fatores de risco Limite: Humanos País/Região como assunto: América do Sul / Peru Idioma: Espanhol Revista: Rev. méd. panacea Ano de publicação: 2019 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Regional de Ica/PE / Universidad Nacional San Luis Gonzaga/PE