Abstract INTRODUCTION:
Rapid diagnostic tests (RDTs) are selected based on their performances. Here, we compared the diagnostic performance of different malaria RDTs.METHODS:
Febrile patients were tested for malaria using Vikia Malaria Pf/Pan, Meriline-Meriscreen Pf/Pv/Pan, Right Sign Malaria Pf/Pan, and Right Sign Malaria Pf RDTs at Melen Regional Hospital in Gabon.RESULTS:
In total, 120 of 274 tested children (43.8%) had malaria. The sensitivity was > 95% for all RDTs, while the specificity was > 85% for two tests. One test generated invalid tests (8%).CONCLUSIONS:
Based on their performances, all tests except one may be recommended for malaria diagnosis.