Supervivencia en pacientes con falla cardiaca y desfibrilador automático implantable en una unidad de electrofisiología de Pereira, Colombia / Survival in patients with heart failure and implantable cardioverter-defibrillator in an electrophysiological unit in Pereira, Colombia
Arch. med
; 21(1): 35-44, 2021/01/03.
Article
em Es
| LILACS
| ID: biblio-1148355
Biblioteca responsável:
CO279.1
RESUMEN
Objetivo:
identificar las variables clínicas que impactan en la mortalidad de los pacientes con falla cardiaca implantados con desfibrilador automático. La terapia con cardiodesfibrilador implantable busca prevenir la muerte súbita cardiaca por arritmias malignas colapsantes. Material ymétodos:
estudio de cohorte retrospectiva. Se incluyó a pacientes con implante de desfibrilador entre los años 2010-2012, con dispositivo funcional, historia clínica y disponibilidad de seguimiento hasta el primer trimestre del 2014.Resultados:
un total de 30 pacientes fueron incluidos, con una supervivencia del 77% a los cuatro años de seguimiento. El 82,7% de los pacientes presentó cardiopatía isquémica y el promedio de la fracción de eyección ventricular izquierda fue 27,8 ± 6,3. El tiempo promedio de uso del desfibrilador fue de 2,1 años, la tasa de peligro mayor reportada fue del 6% para los días 759 y 760. Se encontró una asociación entre una duración del QRS mayor a 120 ms (HR= 7,7, IC 90%= 1,77- 33,6; p=0,022), fibrilación auricular (HR= 4,2, IC 90%=1,13-15,68; p=0,072) y el uso de beta-bloqueadores (HR= 0,15, IC 90%= 0,03 0,64; p=0,031) con el tiempo de supervivencia.Discusión:
la prevención de muerte súbita está condicionada por la optimización farmacológica, así como las anomalías estructurales y de la conducción eléctrica, por lo cual se debe aumentar el seguimiento en estos casos y el ajuste de la terapia farmacológica.Conclusiones:
el uso de beta bloqueadores en pacientes con falla cardiaca con fibrilación auricular y duración del QRS mayor de 120 ms es un factor protector..AuABSTRACT
Objective:
to identify the clinical variables that impact on the mortality of patients with heart failure implanted with cardioverter defibrillator. Implantable cardioverter defibrillator therapy seeks to prevent sudden cardiac death by collapsing malignant arrhythmias. Material ymethods:
retrospective cohort study. Patients with a defibrillator implant from the year 2010 to the year 2012 were included, with functional device, clinical history and availability of follow-up until the first quarter of 2014.Results:
a total of 30 patients were included, with a 77% survival at four years of follow-up. 82.7% of the patients presented with ischemic heart disease and the mean left ventricular ejection fraction was 27.8 ± 6.3. The mean time of use of the defibrillator was 2.1 years, the reported mayor danger rate was 6% for days 759 and 760. An association was found between a QRS mayor duration at 120 ms (HR = 7.7, 90% CI = 1.77-33.6, p = 0.022), atrial fibrillation (HR = 4.2, 90% CI = 1.13-15.68, p = 0.072), and beta- blockers (HR = 0.15, 90% CI = 0.03-0.64, p = 0.031) with survival time.Discussion:
the prevention of death is conditioned by pharmacological optimization, as well as structural and electrical conduction anomalies, so the monitoring and adjustment of pharmacological therapy should be increased.Conclusions:
the use of beta-blockers in patients with atrial fibrillation and QRS duration greater than 120 ms is a protective factor..AuPalavras-chave
Texto completo:
1
Índice:
LILACS
Assunto principal:
Análise de Sobrevida
/
Desfibriladores Implantáveis
Tipo de estudo:
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Humans
País/Região como assunto:
America do sul
/
Colombia
Idioma:
Es
Revista:
Arch. med
Assunto da revista:
MEDICINA
Ano de publicação:
2021
Tipo de documento:
Article