Your browser doesn't support javascript.
loading
Evaluation of the Genotoxicity of Endodontic Materials for Deciduous Teeth Using the Comet Assay
Santos, Nilton Cesar Nogueira dos; Soares, Bruno Marques; Pessoa, Cláudia do Ó; Freitas, Livia Maria Andrade de; Cruz, João Pedro Pedrosa; Ramos, Maria Emília Santos Pereira; Pithon, Matheus Melo; Graduate Program in BiotechnologyCerqueira, Eneida Moraes de Marcílio.
  • Santos, Nilton Cesar Nogueira dos; State University of Southwest of Bahia. Department of Health. Jequié. BR
  • Soares, Bruno Marques; Federal University of Ceará. Department of Pharmacology. Fortaleza. BR
  • Pessoa, Cláudia do Ó; Federal University of Ceará. Department of Pharmacology. Fortaleza. BR
  • Freitas, Livia Maria Andrade de; State University of Southwest of Bahia. Department of Health. Jequié. BR
  • Cruz, João Pedro Pedrosa; State University of Southwest of Bahia. Department of Health. Jequié. BR
  • Ramos, Maria Emília Santos Pereira; State University of Feira de Santana. Department of Health. Feira de Santana. BR
  • Pithon, Matheus Melo; State University of Southwest of Bahia. Department of Health. Jequié. BR
  • Graduate Program in BiotechnologyCerqueira, Eneida Moraes de Marcílio; State University of Feira de Santana. Department of Biological Science. Graduate Program in BiotechnologyCerqueira, Eneida Moraes de Marcílio. Feira de Santana. BR
Artigo em Inglês | LILACS, BBO | ID: biblio-1250451
ABSTRACT
ABSTRACT Objective: To evaluate genotoxicity of zinc oxide, P. A. calcium hydroxide, mineral trioxide aggregate and an iodoform paste using comet assay on human lymphocytes. Material and Methods: Two positive controls were used: methyl-methanesulfonate for the P.A. calcium hydroxide and mineral trioxide aggregate; and doxorubicin for the iodoform paste and zinc oxide. There were also two negative controls: distilled water for the P.A. calcium hydroxide and mineral trioxide aggregate; and DMSO for the iodoform paste and zinc oxide. Comets were identified using fluorescence microscopy and 100 of them were counted on each of the three slides analyzed per drug test. A damage index was established, taking into consideration the score pattern that had previously been determined from the size and intensity of the comet tail. Analysis of variance, followed by Tukey's test, was used to compare the means of the DNA damage indices. Results: The DNA damage index observed for mineral trioxide aggregate (7.08 to 8.58) and P.A. calcium hydroxide (6.50 to 8.33), which were similar to negative control index. On the other hand, damage index for zinc oxide (104.7 to 218.50) and iodoform paste (115.7 to 210.7) were similar to positive control index. Conclusion: Iodoform paste and zinc oxide showed genotoxicity at all concentrations used.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Dente Decíduo / Óxido de Zinco / Ensaio Cometa / Genotoxicidade / Testes de Mutagenicidade Tipo de estudo: Estudos de avaliação / Estudo prognóstico Limite: Humanos País/Região como assunto: América do Sul / Brasil Idioma: Inglês Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: Odontologia Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Ceará/BR / State University of Feira de Santana/BR / State University of Southwest of Bahia/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Dente Decíduo / Óxido de Zinco / Ensaio Cometa / Genotoxicidade / Testes de Mutagenicidade Tipo de estudo: Estudos de avaliação / Estudo prognóstico Limite: Humanos País/Região como assunto: América do Sul / Brasil Idioma: Inglês Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: Odontologia Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Ceará/BR / State University of Feira de Santana/BR / State University of Southwest of Bahia/BR