RESUMEN

Objetivo:

El propósito del presente estudio fue evaluar comparativamente las características de porosidad entre el cemento Portland, MTA Angelus® y Biodentine Septodont®, observados con un microscopio electrónico de barrido. Materiales y

métodos:

Se prepararon los cementos según las indicaciones del fabricante y se empaquetaron en tubos cilíndricos de polietileno con un diámetro interno de 10 mm y una altura de 5 mm. Se analizó la porosidad de las muestras mediante el microscopio electrónico de barrido. El análisis estadístico se realizó utilizando la prueba Kruskal-Wallis. El nivel de significancia se estableció en 0,05

Resultados:

Se observó la descripción de la media de los valores del diámetro de los poros, y el tamaño mayor correspondió al cemento Portland (11,07). Existen diferencias significativas entre las medias del diámetro de los poros con un p = 0,05. Se identificó que el MTA Angelus® tiene la mayor cantidad de poros, le sigue el Biodentine Septodont® y, por último, el Portland. Se comparó la cantidad de poros entre los tres cementos y no se encontraron diferencias significativas, con un p = 0,09.

Conclusión:

Los análisis realizados en los cementos endodónticos dieron como resultado que el cemento Portland tiene mayor diámetro de poro a diferencia de los otros dos, lo cual implica que tanto el Biodentine Septodont® como el MTA Angelus® tienen mejores propiedades de resistencia y permeabilidad para evitar la microfiltración, y por tanto son mejores para la solución de casos clínicos. (AU)
ABSTRACT

Objective:

The purpose of this study was to compare the porosity characteristics of Portland cement, mineral trioxide aggregate (MTA) Angelus® and Biodentine Septodont® by scanning electron microscopy. Materials and

Methods:

Cements were prepared according to the manufacturer's instructions and packed in cylindrical polyethylene tubes with an internal diameter of 10 mm and a height of 5 mm. The porosity of the samples was analyzed using scanning electron microscopy. Statistical analyses were performed using the Kruskall Wallis test. The level of significance was established at 0.05.

Results:

The largest size mean diameter valus was found with Portland cement (11.07). There were significant differences between the mean pore diameters (p = 0.05). MTA Angelus® had the largest number of pores, followed by Biodentine Septodont®, and finally, Portland. There were no significant differences in the pores of the three cements (p = 0.09).

Conclusion:

The results of this comparative analysis of endodontic cements showed that Portland cement has a larger pore diameter than MTA Angelus® and Biodentine Septodont®, demonstrating that these latter two cements present better resistance and permeability properties, and thereby prevent microleakage. (AU)
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Microscopia Eletrônica / Porosidade / Cimentos Dentários Tipo de estudo: Estudo observacional / Estudo de prevalência / Estudo prognóstico / Fatores de risco Idioma: Espanhol Revista: Rev. cient. odontol Ano de publicação: 2021 Tipo de documento: Artigo Instituição/País de afiliação: Universidad Científica del Sur/PE

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Microscopia Eletrônica / Porosidade / Cimentos Dentários Tipo de estudo: Estudo observacional / Estudo de prevalência / Estudo prognóstico / Fatores de risco Idioma: Espanhol Revista: Rev. cient. odontol Ano de publicação: 2021 Tipo de documento: Artigo Instituição/País de afiliação: Universidad Científica del Sur/PE