Your browser doesn't support javascript.
loading
Analytical and clinical performance of molecular assay used by the Brazilian public laboratory network to detect and discriminate Zika, Dengue and Chikungunya viruses in blood
Ribeiro, Marisa O.; Godoy, Daniela T.; Fontana-Maurell, Marcela; Costa, Elaine M.; Andrade, Elisabete F.; Rocha, Daniele R.; Ferreira, Antônio G.P.; Brindeiro, Rodrigo; Tanuri, Amilcar; Alvarez, Patrícia.
  • Ribeiro, Marisa O.; Oswaldo Cruz Foundation/Fiocruz. Institute of Technology in Immunobiology Bio-Manguinhos. Rio de Janeiro. BR
  • Godoy, Daniela T.; Oswaldo Cruz Foundation/Fiocruz. Institute of Technology in Immunobiology Bio-Manguinhos. Rio de Janeiro. BR
  • Fontana-Maurell, Marcela; Oswaldo Cruz Foundation/Fiocruz. Institute of Technology in Immunobiology Bio-Manguinhos. Rio de Janeiro. BR
  • Costa, Elaine M.; Oswaldo Cruz Foundation/Fiocruz. Institute of Technology in Immunobiology Bio-Manguinhos. Rio de Janeiro. BR
  • Andrade, Elisabete F.; Oswaldo Cruz Foundation/Fiocruz. Institute of Technology in Immunobiology Bio-Manguinhos. Rio de Janeiro. BR
  • Rocha, Daniele R.; Oswaldo Cruz Foundation/Fiocruz. Institute of Technology in Immunobiology Bio-Manguinhos. Rio de Janeiro. BR
  • Ferreira, Antônio G.P.; Oswaldo Cruz Foundation/Fiocruz. Institute of Technology in Immunobiology Bio-Manguinhos. Rio de Janeiro. BR
  • Brindeiro, Rodrigo; Federal University of Rio de Janeiro. Institute of Biology. Rio de Janeiro. BR
  • Tanuri, Amilcar; Federal University of Rio de Janeiro. Institute of Biology. Rio de Janeiro. BR
  • Alvarez, Patrícia; Oswaldo Cruz Foundation/Fiocruz. Institute of Technology in Immunobiology Bio-Manguinhos. Rio de Janeiro. BR
Braz. j. infect. dis ; 25(2): 101542, 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1278571
ABSTRACT
ABSTRACT In response to the Zika epidemics in Brazil, the ZDC molecular assay (Bio-Manguinhos) was developed and registered at the Brazilian Regulatory Agency of Health Surveillance - ANVISA. The circulation of Zika (ZIKV) Dengue (DENV) and Chikungunya (CHIKV) viruses and their clinical similarities are challenges to correctly diagnose these viruses. The simultaneous detection of ZIKV, DENV and CHIKV is an important tool for diagnosis and surveillance. Here, we present the analytical and clinical performance evaluation of ZDC molecular assay (Bio-Manguinhos) at the public health laboratories three years after its registration at ANVISA. The clinical performance demonstrates the ZDC molecular assay (Bio-Manguinhos) has 100% sensitivity and 100% specificity to detect and discriminate ZIKV, CHIKV, and DENV from clinical plasma samples. The ZDC molecular assay (Bio-Manguinhos) results were highly reproducible and no cross-reactivity was seen during testing with a panel of other infectious agents. In conclusion, the ZDC molecular assay (Bio-Manguinhos) is an accurate and reliable tool to monitor Zika, dengue and chikungunya infections in countries like Brazil with simultaneous circulation of the three viruses.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Zika virus / Infecção por Zika virus Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Limite: Humanos País/Região como assunto: América do Sul / Brasil Idioma: Inglês Revista: Braz. j. infect. dis Assunto da revista: Doenças Transmissíveis Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Rio de Janeiro/BR / Fiocruz+BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Zika virus / Infecção por Zika virus Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Limite: Humanos País/Região como assunto: América do Sul / Brasil Idioma: Inglês Revista: Braz. j. infect. dis Assunto da revista: Doenças Transmissíveis Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Rio de Janeiro/BR / Fiocruz+BR