Your browser doesn't support javascript.
loading
Densidad vascular/de perfusión en dos protocolos de angiotomografía de coherencia óptica ¿Intercambiables? / Vessel/ perfusion density in two optical coherence tomography angiography protocols. Interchangeable?
Monares-Zepeda, Gerardo; Montano, Margarita; Bonilla, Luisa A; Chew-Bonilla, Alan; Lima-Gómez, Virgilio.
Afiliação
  • Monares-Zepeda, Gerardo; Clínica de Microcirugía Ocular Avanzada Dr. Enrique Monares García. Servicio de Retina. Toluca. MX
  • Montano, Margarita; s.af
  • Bonilla, Luisa A; s.af
  • Chew-Bonilla, Alan; s.af
  • Lima-Gómez, Virgilio; Hospital Juárez de México. Servicio de Oftalmología. Ciudad de México. MX
Gac. méd. Méx ; Gac. méd. Méx;157(2): 166-173, mar.-abr. 2021. tab, graf
Article em Es | LILACS | ID: biblio-1279097
Biblioteca responsável: BR1.1
RESUMEN
Resumen

Introducción:

Distintos protocolos de angiotomografía de coherencia óptica evalúan la mácula.

Objetivo:

R2) entre las densidades vascular y de perfusión de dos protocolos de angiotomografía de coherencia óptica, para determinar si sus mediciones podían intercambiarse.

Método:

Estudio observacional, comparativo, prospectivo, transversal entre dos protocolos de angiotomografía de coherencia óptica (AngioPlex, Zeiss) en sujetos sanos. Se identificó la R2 entre las densidades vascular y de perfusión central, interna y completa (protocolo de 3 x 3 mm), y central, interna, externa y completa (protocolo de 6 x 6 mm).

Resultados:

78 ojos, mediana de edad 23 años. Hubo R2 altas entre las densidades interna y completa del protocolo de 3 x 3 mm (0.96), externa y completa del de 6 x 6 mm (0.96), y centrales vasculares y de perfusión (≥ 0.96); la R2 entre las densidades centrales vascular y de perfusión de distintos protocolos fue ≤ 0.71.

Conclusiones:

Las densidades vasculares y de perfusión tienen R2 alta dentro de un protocolo, pero no entre protocolos, porque estos miden preferentemente zonas distintas, lo cual limita intercambiar mediciones.
ABSTRACT
Abstract

Introduction:

Different optical coherence tomography angiography (OCTA) scanning protocols evaluate the macula.

Objective:

To compare the determination coefficients (R2) between vessel and perfusion densities of two OCTA scanning protocols, to learn whether their metrics could be interchanged.

Method:

Non-experimental, comparative, prospective, observational, cross-sectional study, between two OCTA scanning protocols (Angioplex, Zeiss) in healthy subjects. We found the R2 between central, inner, and full densities (3 x 3 mm protocol), and between central, inner, outer and full densities (6 x 6 mm protocol), both for vessel and perfusion densities.

Results:

78 eyes, median age 23 years. There were high R2 between inner and full densities in the 3 x 3 mm protocol (0.96), between outer and full densities in the 6 x 6 mm protocol (0.96) and between central vessel and perfusion densities (≥0.96); R2 between central vessel and perfusion densities of different protocols (≤0.71).

Conclusions:

Vessel and perfusion densities have high determination coefficients within a scanning protocol, but not between protocols, because each preferentially measures different macular areas. The metrics of different protocols should not be interchanged for follow-up.
Assuntos
Palavras-chave

Texto completo: 1 Índice: LILACS Assunto principal: Angiografia / Tomografia de Coerência Óptica / Macula Lutea Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: Es Revista: Gac. méd. Méx Assunto da revista: MEDICINA Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Índice: LILACS Assunto principal: Angiografia / Tomografia de Coerência Óptica / Macula Lutea Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: Es Revista: Gac. méd. Méx Assunto da revista: MEDICINA Ano de publicação: 2021 Tipo de documento: Article