Your browser doesn't support javascript.
loading
Impacto de la técnica de Cusp-Overlap en el requerimiento de marcapasos luego de un implante valvular aórtico percutáneo / Impact of Cusp-Overlap Technique on Pacemaker Requirement after Transcatheter Aortic Valve Implantation
SZTEJFMAN, MATÍAS; GIULIANI, CARLOS MAXIMILIANDO; PERALTA, SEBASTIÁN; ZAIDEL, EZEQUIEL JOSÉ; SZTEJFMAN, LUIS CARLOS; BETTINOTTI, MARCELO OMAR.
  • SZTEJFMAN, MATÍAS; Sanatorio Güemes. Servicio de Cardiología intervencionista. AR
  • GIULIANI, CARLOS MAXIMILIANDO; Sanatorio Güemes. Servicio de Cardiología intervencionista. AR
  • PERALTA, SEBASTIÁN; Sanatorio Güemes. Servicio de Cardiología intervencionista. AR
  • ZAIDEL, EZEQUIEL JOSÉ; Sanatorio Güemes. Servicio de Cardiología intervencionista. AR
  • SZTEJFMAN, LUIS CARLOS; Sanatorio Güemes. Servicio de Cardiología intervencionista. AR
  • BETTINOTTI, MARCELO OMAR; Sanatorio Güemes. Servicio de Cardiología intervencionista. AR
Rev. argent. cardiol ; 89(2): 140-144, abr. 2021. tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1356861
RESUMEN
RESUMEN

Introducción:

Las bradiarritmias persistentes que requieren el implante de un marcapasos definitivo son una complicación frecuente tras el implante valvular aórtico percutáneo (IVAP), pero un implante alto con técnica Cusp-Overlap podría evitar las alteraciones del sistema de conducción.

Objetivo:

El objetivo fue determinar la tasa de uso de marcapasos en pacientes que recibieron IVAP con la técnica convencional coplanar en comparación con Cusp-Overlap. Material y

métodos:

Entre 2017 y 2019 se analizaron 65 pacientes consecutivos de dos centros, que recibieron válvulas EvolutR o Evolut-Pro 50 implante coplanar y 15 Cusp-Overlap.

Resultados:

La edad promedio era 80 años y no hubo diferencias en el riesgo por puntaje EuroSCORE. Los procedimientos con la técnica de Cusp-Overlap presentaron 0% de requerimiento de marcapasos en comparación con 24,9% en el implante convencional (p = 0,041). También hubo menos complicaciones mayores (6,67% vs 42%; OR = 0,09; IC 95% 0,01-0,8; p = 0,011).

Conclusiones:

En esta cohorte el IVAP con la técnica de Cusp-Overlap se asoció con una necesidad de marcapasos nula. Dado el potencial impacto a gran escala se necesita validar externamente los resultados obtenidos.
ABSTRACT
ABSTRACT

Background:

Persistent bradyarrhythmias requiring permanent pacemaker implantation are a common complication after transcatheter aortic valve implantation (TAVI), but high implantation with cusp-overlap technique could prevent conduction system disturbances.

Objective:

The aim of this study was to assess the rate of pacemaker use in patients who received TAVI with conventional coplanar technique compared with cusp-overlap technique.

Methods:

A total of 65 consecutive patients from two centers receiving Evolut-R or Evolut-Pro valve implantation, 50 coplanar and 15 cusp-overlap, were analyzed between 2017 and 2019.

Results:

Mean age was 80 years, and there were no differences in risk according to the EuroSCORE. The rate of pacemaker requirement was 0% in cusp-overlap procedures compared with 24.9% in those with conventional implantation; p=0.041). In addition, cusp-overlap implants presented lower rate of major complications (6.67% vs. 42%; OR=0.09; 95% CI 0.01-0.8; p=0.011).

Conclusions:

In this cohort, TAVI procedure with cusp-overlap technique was associated with null pacemaker requirement. Given the potential large-scale impact, external validation of results is needed.


Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Espanhol Revista: Rev. argent. cardiol Assunto da revista: Cardiologia / Doen‡as Cardiovasculares Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Argentina Instituição/País de afiliação: Sanatorio Güemes/AR

Similares

MEDLINE

...
LILACS

LIS