Your browser doesn't support javascript.
loading
Reemplazo de aorta ascendente con paro circulatorio con hipotermia sistémica moderada y perfusión cerebral retrógrada / Total replacement of the ascending aorta with moderate systemic hypothermic circulatory arrest and retrograde cerebral perfusion
Zalaquett, Ricardo; González, Katia; Borchert, Evelyn; Sepúlveda, Verónica.
  • Zalaquett, Ricardo; Pontificia Universidad Católica de Chile. Facultad de Medicina. Sección de Cirugía Cardiaca. CL
  • González, Katia; Pontificia Universidad Católica de Chile. Facultad de Medicina. División de Anestesiología. CL
  • Borchert, Evelyn; Pontificia Universidad Católica de Chile. Facultad de Medicina. División de Anestesiología. CL
  • Sepúlveda, Verónica; Pontificia Universidad Católica de Chile. Facultad de Medicina. División de Anestesiología. CL
Rev. chil. cardiol ; 40(1): 11-19, abr. 2021. tab
Artigo em Espanhol | LILACS | ID: biblio-1388073
RESUMEN
Resumen: Antecedentes: El daño neurológico es una complicación devastadora de la cirugía con paro circulatorio del cayado aórtico y aorta ascendente. La perfusión anterógrada del encéfalo permite disminuir la incidencia de esta complicación, pero es un procedimiento engorroso que interfiere el campo quirúrgico. Para procedimientos más simples que requieran de paro circulatorio de menor duración, la Perfusión Cerebral Retrógrada (PCR) es una alternativa válida. Objetivo: Evaluar nuestros resultados en la cirugía del reemplazo total de la aorta ascendente tubular con paro circulatorio con hipotermia sistémica moderada y PCR. Material y Método: Entre enero de 2015 y enero de 2020 se identificaron los pacientes en la Base de Datos del Servicio de Cirugía Cardiaca de nuestra institución, se revisaron los protocolos operatorios, registros de perfusión y epicrisis, para obtener datos demográficos, clínicos y quirúrgicos pertinentes. La supervivencia alejada se certificó a través del "Servicio Registro Civil e Identificación de Chile". Resultados: En el periodo en estudio, 27 pacientes (21 hombres) tuvieron un reemplazo total de la aorta ascendente tubular con paro circulatorio con hipotermia moderada y PCR. Ocho pacientes tenían una cirugía previa; 7 de estos un reemplazo valvular aórtico. El 75% de los otros 20 pacientes tenía una válvula aórtica bicúspide. El diámetro máximo de la aorta ascendente fue en promedio 53,7 mm (45 a 67), y fue reemplazada en el 52% de los casos con un tubo protésico de 34 mm (promedio:32,4 mm; margen:30 a 34 mm). En 20 pacientes se efectuó un reemplazo valvular aórtico (15 con prótesis biológica). El tiempo promedio de circulación extracorpórea fue 174,6 min (97 a 243) y la temperatura sistémica mínima promedio fue 21ºC (18 a 25). El tiempo promedio de paro circulatorio fue 22,3 min (12 a 40) y de PCR 13 min (6 a 27). No hubo mortalidad operatoria. La morbilidad más frecuente fue la fibrilación auricular (33%). Una paciente presentó un episodio convulsivo aislado y otro fue reoperado por hemorragia postoperatoria. Una paciente falleció a los 48 meses de su operación. Conclusión: El paro circulatorio con hipotermia sistémica moderada y PCR para la cirugía de reemplazo total de la aorta ascendente facilitó la operación, con baja mortalidad y morbilidad en este grupo de pacientes.
ABSTRACT
Abstract: Background. Neurological damage is a devastating complication of aortic arch and ascending aorta surgery with deep hypothermic circulatory arrest. Antegrade cerebral perfusion significantly decreases the incidence of this complication, but it is a cumbersome procedure that interfere the surgical field. For more simple procedures, requiring a shorter period of circulatory arrest, retrograde cerebral perfusion (RCP) would be a valid alternative. Objective. To evaluate the results of total surgical replacement of the tubular ascending aorta with moderate hypothermic circulatory arrest and retrograde cerebral perfusion (RCP). Methods. Patients operated between January 2015 and January 2020 were included.Demographic, clinical and surgical information was obtained from the operatives notes, perfusion registry and discharge reports. Long-term survival was certified by the "Chilean Civil and Identification Registry". Results. 27 patients (21 men) underwent a total replacement of the tubular ascending aorta with circulatory arrest with moderate hypothermia and RCP. Eight patients had been previously operated on;7 of them had a previous aortic valve replacement. Of the remaining 20 patients, 75% had a bicuspid aortic valve. Average maximum diameter of the ascending aorta was 53.7 mm (45 - 67). Average size of the ascending aorta replacement graft was 32.4 mm (30 -34). In 20 patients a concomitant aortic valve replacement was performed (15 with a biological valve). Mean extracorporeal circulation time was 174.6 min (97 - 243) and mean minimal systemic temperature was 21ºC (18 - 25). Mean circulatory arrest time was 22.3 min (12 - 40) and mean RCP time was 13 min (6 - 27), There was no operative mortality. Atrial fibrillation was the most frequent post-operative morbidity (33%). One patient presented an isolated convulsive episode and another was re-operated due to postoperative hemorrhage. One patient died, 48 months after her operation. Conclusion. Moderate hypothermic circulatory arrest with RCP simplifies total tubular ascending aorta replacement, with low mortality and morbidity.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Perfusão / Circulação Cerebrovascular / Parada Circulatória Induzida por Hipotermia Profunda / Aneurisma da Aorta Ascendente Tipo de estudo: Guia de Prática Clínica Limite: Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. chil. cardiol Assunto da revista: Cardiologia Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Chile Instituição/País de afiliação: Pontificia Universidad Católica de Chile/CL

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Perfusão / Circulação Cerebrovascular / Parada Circulatória Induzida por Hipotermia Profunda / Aneurisma da Aorta Ascendente Tipo de estudo: Guia de Prática Clínica Limite: Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. chil. cardiol Assunto da revista: Cardiologia Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Chile Instituição/País de afiliação: Pontificia Universidad Católica de Chile/CL