Your browser doesn't support javascript.
loading
Seguridad del implante de lente fáquica ACR-128 tras un año de seguimiento / Safety of an ACR-128 phakic lens implant after one year's follow-up
Cárdenas Díaz, Taimi; Li, Fengqi; Vargas Vergara, Juan P; González Ortega, María F; Guerra Almaguer, Michel.
  • Cárdenas Díaz, Taimi; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Li, Fengqi; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Vargas Vergara, Juan P; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • González Ortega, María F; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Guerra Almaguer, Michel; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
Rev. cuba. invest. bioméd ; 40(4)dic. 2021. tab
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1408581
RESUMEN
Objetivo: Determinar la seguridad de los lentes fáquicos ACR-128 en la corrección de la alta miopía tras un año de implantados. Método: Se realizó un estudio transversal en 67 ojos de 36 pacientes con miopía corregida con lente fáquica ACR-128 (31 con ambos ojos y 5 con un solo ojo). Se determinó preoperatorio y posoperatorio: tensión ocular, pérdida celular endotelial según conteo, coeficiente de variación celular y hexagonalidad. Además de complicaciones posoperatorias y posición del lente respecto a endotelio y cristalino. El análisis estadístico se realizó con la prueba T para datos pareados, con una significación del 95 por ciento. Resultados: Edad media 28,06 ± 6,14 (25 mujeres y 11 hombres). Las complicaciones inmediatas fueron hipotonía OD: 1 (3,03 por ciento), OI: 1 (2,94 por ciento). La irregularidad de la pupila se presentó OD: 1 (3,03 por ciento), OI: 1 (2,94 por ciento) mediata y OD: 1 (3,03 por ciento), OI: 2 (5.88 por ciento) tardía. Tensión ocular promedio total preoperatorio 14,09 ± 2,51 y posoperatorio 14,22 ± 2,64 (p = 0,90). El conteo celular preoperatorio 2667,27 ± 228,72 y posoperatorio 2591,96 ± 301,21, con 2,94 por ciento pérdida endotelial total 75,31 ± 237,41 (p = 0,06). No hubo diferencias en el coeficiente de variación (p = 0,60) ni la hexagonalidad (p = 0,57). Posición del lente respecto al endotelio 2,09 mm y al cristalino 1,08 mm. Conclusiones: El implante de lente fáquica ACR-128 en la corrección de la alta miopía es un tratamiento seguro al no existir complicaciones posquirúrgico ni modificaciones en la tensión ocular y en el endotelio corneal tras un año del implante(AU)
ABSTRACT
Objective: Determine the safety of ACR-128 phakic lenses for high myopia correction one year after implantation. Method: A cross-sectional study was conducted of 67 eyes of 36 patients with myopia corrected with ACR-128 phakic lens implants (31 in both eyes and 5 in one eye). Pre- and postoperative determination was made of ocular tension, endothelial cell loss by count, cell variation coefficient and hexagonality, as well as of postoperative complications and lens position with respect to the endothelium and the crystalline lens. Statistical analysis was based on the paired T-test with a significance level of 95 percent Results: Mean age was 28.06 ± 6.14 (25 women and 11 men). An immediate complication was hypotonia: RE: 1 (3.03 percent), LE: 1 (2.94 percent). Pupil irregularity was mediate: RE: 1 (3.03 percent), LE: 1 (2.94 percent) and late: RE: 1 (3.03 percent), LE: 2 (5.88 percent). Total average ocular tension was 14.09 ± 2.51 preoperative and 14.22 ± 2.64 postoperative (p = 0.90). Cell count was 2667.27 ± 228.72 preoperative and 2591.96 ± 301.21 postoperative, with 2.94 percent total endothelial loss 75.31 ± 237.41 (p = 0.06). Differences were not found in the variation coefficient (p = 0.60) or in hexagonality (p = 0.57). Lens position was 2.09 mm with respect to the endothelium and 1.08 mm with respect to the crystalline lens. Conclusions: ACR-128 phakic lens implantation for high myopia correction is a safe procedure with no postoperative complications or modifications in ocular tension or the corneal endothelium after one year's follow-up(AU)
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Segurança / Lentes Intraoculares Fácicas / Miopia Tipo de estudo: Estudo observacional / Estudo de prevalência Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. cuba. invest. bioméd Assunto da revista: Medicina Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Segurança / Lentes Intraoculares Fácicas / Miopia Tipo de estudo: Estudo observacional / Estudo de prevalência Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. cuba. invest. bioméd Assunto da revista: Medicina Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU