Mayor presión y área de contacto en reparación transósea cruzada de manguito rotador versus reparación simple / Increased pressure and contact area in rotator cuff crossed versus simple transosseous repair
Contreras, Julio José; Liendo, Rodrigo; Soza, Francisco.
  • Contreras, Julio José; Instituto Traumatológico. Santiago. CL
  • Liendo, Rodrigo; Pontificia Universidad Católica de Chile. Santiago. CL
  • Soza, Francisco; Pontificia Universidad Católica de Chile. Santiago. CL
Rev. chil. ortop. traumatol ; 62(3): 159-167, dic. 2021. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1427061
RESUMEN
OBJETIVO: Comparar la presión y el área de contacto en la interfase tendón-huella de una reparación realizada con suturas transóseas simples y cruzadas. MÉTODOS: Se utilizaron doce hombros de cordero para simular una rotura de manguito rotador. Se midió el área de contacto en la interfase tendón-huella con láminas sensibles a presión; luego, se midió la presión con un sensor digital. Se registró la presión basal durante la aplicación de carga cíclica y al final de la intervención. Se compararon 2 reparaciones: 2 túneles transóseos con nudos simples (TOS; n = 6) y 2 túneles transóseos con nudos cruzados (TOC; n = 6), utilizando FiberWire #2. Se realizaron 1.400 ciclos, con una frecuencia 2,5 Hz y una carga de 5 N. Se utilizó la prueba de Mann-Whitney, y ae consideraron significativos valores de p < 0,05. RESULTADOS: La reparación TOS presentó un 50,9 ± 12,7% distribución de presiones en comparación con 72,2 ± 5,3% en la reparación TOC (p < 0,009). La presión promedio en la reparación TOS fue 0,7 ± 0,1 MPa en comparación con 1,1 ± 0,2 MPa en la reparación TOC (p < 0,007). La reparación TOS registró una presión basal de 5,3 ± 5,3 N, presión final de 3,8 ± 4,6 N, y una variación de 51,7 ± 38%. La reparación TOC registró una presión basal de 10,7 ± 1,8 N, presión final de 12,9 ± 8,7 N, y una variación de 114,9 ± 65,9% (p < 0,044; p < 0,022; y p < 0,017, respectivamente). CONCLUSIÓN: La reparación TOC presenta mayor presión a nivel de la interfase tendón-hueso, menor pérdida de fuerza de contacto ante cargas cíclicas, y una mejor distribución de fuerza en la huella al comparar con la reparación TOS, lo que se podría traducir en mejor cicatrización tendínea.
ABSTRACT
OBJETIVE: To compare the pressure and contact area at the tendon-footprint interface of a repair performed with simple and crossed transosseous sutures. METHODS: Twelve lamb shoulders were used to simulate a rotator cuff tear. The contact area at the tendon-footprint interface was measured with pressure-sensitive films; then, the pressure was measured with a digital sensor. The baseline pressure was recorded during the application of a cyclic load and at the end of the intervention. A total of 2 repairs were compared: 2 transosseous sutures with single knots (STO; n = 6) and 2 transosseous sutures with crossed knots (TOC; n = 6) using FiberWire #2. In total, 1,400 cycles were performed, with a frequency of 2.5 Hz and a load of 5 N. The Mann-Whitney test was used. Values of p < 0.05 were considered significant.RESULTS: The TOS repair presented 50.9 ± 12.7% of pressure distribution compared to 72.2 ± 5.3% in the TOC repair (p < 0.009). The mean pressure in the TOS repair was of 0.7 ± 0.1 MPa compared to 1.1 ± 0.2 MPa in the TOC repair (p < 0.007). The TOS repair registered a basal pressure of 5.3 ± 5.3 N, a final pressure of 3.8 ± 4.6 N, and a variation of 51.7 ± 38%. The TOC repair registered a basal pressure of 10.7 ± 1.8 N, a final pressure of 12.9 ± 8.7 N, and a variation of 114.9 ± 65.9% (p < 0.044; p < 0.022; and p < 0.017 respectively).CONCLUSION: The TOC repair presents higher pressure at the tendon-bone interface, less loss of contact force under cyclic loads, and a better distribution of force on the footprint when compared with the TOS repair, which could translate into better tendon healing.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Traumatismos dos Tendões / Manguito Rotador / Procedimentos Ortopédicos Limite: Animais Idioma: Espanhol Revista: Rev. chil. ortop. traumatol Assunto da revista: Ortopedia / Traumatologia Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Chile Instituição/País de afiliação: Instituto Traumatológico/CL / Pontificia Universidad Católica de Chile/CL

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Traumatismos dos Tendões / Manguito Rotador / Procedimentos Ortopédicos Limite: Animais Idioma: Espanhol Revista: Rev. chil. ortop. traumatol Assunto da revista: Ortopedia / Traumatologia Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Chile Instituição/País de afiliação: Instituto Traumatológico/CL / Pontificia Universidad Católica de Chile/CL