Your browser doesn't support javascript.
loading
Deflection of tandem archwire in a specific self-ligating metal bracket system: an in vitro study
CATTANI, Lourenço; CORRER-SOBRINHO, Lourenço; NEVES, José Guilherme; VALDRIGHI, Heloísa; SANTOS, Eduardo César Almada; COSTA, Ana Rosa.
  • CATTANI, Lourenço; Fundação Herminio Ometto. Department of Orthodontics. Araras. BR
  • CORRER-SOBRINHO, Lourenço; Universidade Estadual de Campinas. Piracicaba Dental School. Department of Restorative Dentistry. Piracicaba. BR
  • NEVES, José Guilherme; Universidade Estadual de Campinas. Piracicaba Dental School. Department of Restorative Dentistry. Piracicaba. BR
  • VALDRIGHI, Heloísa; Fundação Herminio Ometto. Department of Orthodontics. Araras. BR
  • SANTOS, Eduardo César Almada; Universidade Estadual de Campinas. Piracicaba Dental School. Department of Health Sciences, Orthodontics and Pediatric Dentistry. Piracicaba. BR
  • COSTA, Ana Rosa; Fundação Herminio Ometto. Department of Orthodontics. Araras. BR
Braz. oral res. (Online) ; 37: e065, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1439737
ABSTRACT
Abstract The aim of this study was to quantify the force exerted by tandem archwires in a specific system of passive self-ligating bracket. Forty-eight thermo-activated nickel-titanium orthodontic archwires were separated into four groups (n = 12): G1 - two .014" + .014" round archwires; G2 - two .014" + .016" round archwires; G3 - .014" x .025" rectangular archwire; and. G4 - .016" x .022" rectangular archwire. Brackets were fixed onto teeth 1.5 to 2.5 using a device that represented the upper teeth, maintaining an interbracket distance of 6.0 mm. The deflection tests were performed using the structure representative of tooth 1.1 as support on the Instron testing machine at a speed of 2.0 mm/min. The archwires were evaluated at deflections of 0.5 mm, 1.0 mm, and 1.5 mm. The data were analyzed by a generalized linear model, considering values at different deflections as repeated measurements in the same experimental unit (α = 0.5%). At 0.5 mm, higher forces were observed in G2 and G3, which did not differ significantly (p > 0.05). The lowest force was observed in G4 (p < 0.05). At 1.0 mm and 1.5 mm, the highest force was observed in G3, followed by G4 and G2 (p < 0.05). The lowest force was observed in G1 (p < 0.05). In general, tandem archwires (same or different calibers) in a specific passive self-ligating bracket exerted lower force when compared with rectangular archwires.


Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Inglês Revista: Braz. oral res. (Online) Assunto da revista: Odontologia Ano de publicação: 2023 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Fundação Herminio Ometto/BR / Universidade Estadual de Campinas/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Inglês Revista: Braz. oral res. (Online) Assunto da revista: Odontologia Ano de publicação: 2023 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Fundação Herminio Ometto/BR / Universidade Estadual de Campinas/BR