Your browser doesn't support javascript.
loading
Parámetros biométricos oculares en candidatos a cirugía de catarata / Ocular biometric parameters in cataract surgery candidates
Corredor-Arroyo, Jennifer; Hoyos-Córdoba, Liliana; Bechara-Castilla, Rolando; Barandica-Acosta, Milena; Ramos-Clason, Enrique.
  • Corredor-Arroyo, Jennifer; Universidad del Sinú. Monteria. CO
  • Hoyos-Córdoba, Liliana; Universidad del Sinú. Clínica Oftalmológica de Cartagena. Monteria. CO
  • Bechara-Castilla, Rolando; Universidad del Sinú. Clínica Oftalmológica de Cartagena. Monteria. CO
  • Barandica-Acosta, Milena; Universidad del Sinú. Monteria. CO
  • Ramos-Clason, Enrique; Universidad del Sinú. Monteria. CO
Rev. Soc. Colomb. Oftalmol ; 54(1): 39-45, 2021. graf
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1451253
RESUMEN

Introducción:

Las estructuras ópticas pueden variar en su configuración y medida dependiendo de la edad, el sexo y la raza, por lo que su medición previa a la cirugía es un pilar fundamental para el cálculo correcto del lente intraocular. Caracterizar los rangos normales de estos parámetros en nuestra población suministra información importante que puede mejorar los resultados visuales tras la cirugía de catarata y alertar en aquellos casos que distan de la media de los rangos conocidos.

Objetivo:

Describir los parámetros biométricos oculares en pacientes candidatos a cirugía de catarata y analizar sus variaciones según la edad y el sexo.

Método:

Estudio observacional descriptivo, de corte transversal. Análisis retrospectivo de biometrías oculares realizadas con reflectometría óptica de baja coherencia en pacientes candidatos a cirugía de catarata.

Resultados:

Se evaluaron 820 ojos de 820 pacientes candidatos a cirugía de catarata, con una edad media de 68.1 ± 11.1 años, el 53.7% de sexo femenino. Los parámetros oculares promedios encontrados fueron longitud axial (AL) 23.39 ± 1.11 mm, profundidad de cámara anterior (ACD) 3.37 ± 0.49 mm, astigmatismo corneal (AST) 1.09 ± 0.85 D, espesor corneal central (CCT) 529.43 ± 35.02 µm, poder queratométrico (K) 43.81 ± 1.64 D, queratometría plana 43.28 ± 1.69 D, queratometría curva 44.37 ± 1.74 D y distancia blanco a blanco 11.82 ± 0.52 mm. El promedio de AL y ACD fue mayor en los hombres que en las mujeres (p < 0.0001), y con el aumento de la edad el AST y el K mostraron una tendencia al incremento. Se encontró un 23.78% de astigmatismo con la regla, un 54.88% de astigmatismo contra la regla y un 21.34% de astigmatismo oblicuo.

Conclusiones:

El perfil de los datos biométricos evidenció diferencias significativas entre sexos y grupos de edad. Se encontró una buena correlación entre la AL, la ACD y la potencia corneal, y los promedios encontrados se corresponden bien con los de otras poblaciones de similar origen étnico.
ABSTRACT

Introduction:

Optical structures can vary in their configuration and measurement depending on age, sex and race, so their measurement, prior to surgery, is a fundamental pillar for the correct calculation of the intraocular lens. Characterizing the normal ranges of these parameters in our population provides important information that can improve the visual results of cataract surgery and alert in those cases that are far from the mean of the known ranges.

Objective:

To describe the ocular biometric parameters in cataract surgery candidates.

Method:

Descriptive, cross-sectional study. Retrospective analysis of biometric parameters measured by optical low-coherence reflectometry in cataract surgery candidates.

Results:

The study evaluated 820 eyes of 820 cataract patients, the mean age was 68.1 ± 11.1 years, 53.7% female. Mean ocular parameters found were axial length (AL) 23.39 ± 1.11 mm, anterior chamber depth (ACD) 3.37 ± 0.49 mm, corneal astigmatism (AST) 1.09 ± 0.85 D, central corneal thickness (CCT) 529.43 ± 35.02 µm, keratometry (K) 43.81 ± 1.64 D, flat keratometry (K1) 43.28 ± 1.69 D, steep keratometry (K2) 44.37 ± 1.74 D and white-to-white distance (WTW) 11.82 ± 0.52 mm. Mean AL and ACD were significantly longer in men (p < 0.0001) and with increasing age, AST and K showed an upward trend. 23.78% of astigmatism with the rule, 54.88% of astigmatism against the rule and 21.34% of oblique astigmatism were found.

Conclusions:

The profile of the biometric data showed significant differences between sex and age groups, a good correlation was found between axial length, chamber depth and keratometry. The averages found correspond well to those of other populations of similar ethnic origin

Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Biometria Tipo de estudo: Estudo observacional / Estudo de prevalência Limite: Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. Soc. Colomb. Oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Universidad del Sinú/CO

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Biometria Tipo de estudo: Estudo observacional / Estudo de prevalência Limite: Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. Soc. Colomb. Oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Universidad del Sinú/CO