Your browser doesn't support javascript.
loading
Sensitivity and specificity of a syphilis rapid diagnostic test in blood donors' samples
Arai, Carolina; Lemos-Machado, Juliano Alves; Aun, Marcelo Vivolo; Bonet-Bub, Carolina; Santos, Leandro Dinalli; Miranda, Angelica Espinosa; Avelino-Silva, Vivian I..
  • Arai, Carolina; Faculdade Israelita de Ciências da Saúde Albert Einstein. Hospital Israelita Albert Einstein. São Paulo. BR
  • Lemos-Machado, Juliano Alves; Faculdade Israelita de Ciências da Saúde Albert Einstein. Hospital Israelita Albert Einstein. São Paulo. BR
  • Aun, Marcelo Vivolo; Faculdade Israelita de Ciências da Saúde Albert Einstein. Hospital Israelita Albert Einstein. São Paulo. BR
  • Bonet-Bub, Carolina; Hospital Israelita Albert Einstein. Departamento Hemoterapia e Terapia Celular. São Paulo. BR
  • Santos, Leandro Dinalli; Hospital Israelita Albert Einstein. Departamento Hemoterapia e Terapia Celular. São Paulo. BR
  • Miranda, Angelica Espinosa; Universidade Federal do Espírito Santo. Departamento de Medicina Social. Vitória. BR
  • Avelino-Silva, Vivian I.; Faculdade Israelita de Ciências da Saúde Albert Einstein. Hospital Israelita Albert Einstein. São Paulo. BR
Braz. j. infect. dis ; 27(6): 103689, 2023. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1528089
ABSTRACT
Abstract Rapid Diagnostic Tests (RDT) are useful to identify syphilis cases, particularly for hard-to-reach populations and if laboratory services are scarce. However, RDT performance may be suboptimal. We aimed to assess the sensitivity and specificity of a syphilis RDT using well-characterized blood donors' samples. We categorized samples from 811 blood donors into five groups: 1 - Samples with reactive Chemiluminescence (QML), FTA-Abs, and VDRL; 2 - Samples with reactive QML and FTA-Abs, and nonreactive VDRL; 3 - Samples with reactive QML, and nonreactive for other markers (false-positives); 4 - Controls with nonreactive QML; and 5 - Samples reactive for HIV, with nonreactive QML. Sensitivity was tested in groups 1 (overall and according to VDRL titers) and 2; specificity was tested in groups 3‒5. The RDT had high specificity, even in samples reactive for HIV. The sensitivity was high (91.9%) in samples with reactive VDRL but varied between 75.0%‒100% according to VDRL titers. The overall sensitivity was lower (81.3%) in samples with reactive FTA-Abs and nonreactive VDRL. The RDT is a useful tool to detect active syphilis but may be more limited for cases with very early or remote infection, or those with prior treatment. When higher sensitivity is needed, additional strategies including recurrent testing or laboratory-based tests may be required.


Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Estudo diagnóstico Idioma: Inglês Revista: Braz. j. infect. dis Assunto da revista: Doenças Transmissíveis Ano de publicação: 2023 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade Israelita de Ciências da Saúde Albert Einstein/BR / Hospital Israelita Albert Einstein/BR / Universidade Federal do Espírito Santo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Estudo diagnóstico Idioma: Inglês Revista: Braz. j. infect. dis Assunto da revista: Doenças Transmissíveis Ano de publicação: 2023 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade Israelita de Ciências da Saúde Albert Einstein/BR / Hospital Israelita Albert Einstein/BR / Universidade Federal do Espírito Santo/BR