Your browser doesn't support javascript.
loading
Manejo de discontinuidad pélvica debido a fractura de acetábulo mediante cirugía de revisión de artroplastia de cadera y reemplazo de componente acetabular por anillo de Burch-Schneider: reporte de un caso / Treatment for pelvic discontinuity due to acetabular fracture by means of hip arthroplasty revision surgery and acetabular component replacement using a Burch-Schneider ring: a case report
Castelblanco-Pérez, Julian David; Moreno-Durán, Ricardo Andrés; Ballesteros-Martín, Juan Camilo.
  • Castelblanco-Pérez, Julian David; Clínica de Especialistas de Sogamoso. Sogamoso. CO
  • Moreno-Durán, Ricardo Andrés; Clínica de Especialistas de Sogamoso. Sogamoso. CO
  • Ballesteros-Martín, Juan Camilo; Clínica de Especialistas de Sogamoso. Sogamoso. CO
Rev. colomb. ortop. traumatol ; 37(4): 1-6, 2023. ilus
Artigo em Espanhol | LILACS | ID: biblio-1532142
RESUMEN
Introducción. La discontinuidad pélvica es una complicación de la artroplastia total de cadera que consiste en la separación de la hemipelvis superior e inferior a través del acetábulo.Presentación del caso. Hombre de 74 años con antecedente de artroplastia total de cadera izquierda que requirió 4 cirugías de revisión de artroplastia, quien consultó al servicio de urgencias de un hospital de segundo nivel de atención de Sogamoso (Colombia) por dolor y limitación de la movilidad de la cadera izquierda durante 7 días luego de haber sufrido trauma por caída de su propia altura en la que el miembro inferior izquierdo recibió la fuerza del impacto. En el examen físico, se evidenció limitación de los arcos de movilidad de la cadera izquierda, por lo que se realizó una radiografía de cadera, en la que se observó fractura del acetábulo, y una tomografía computarizada de cadera, en la que se evidenciaron signos de aflojamiento del componente acetabular y fractura del acetábulo (tipo IIIB según clasificación de Paprosky). Teniendo en cuenta lo anterior, se diagnosticó discontinuidad pélvica y se realizó cirugía de revisión de artroplastia y reemplazo del componente acetabular por un anillo de Burch-Schneider. El paciente tuvo una adecuada evolución posoperatoria con seguimiento a 3 meses. Conclusión. Si bien hay múltiples opciones para el manejo de la discontinuidad pélvica, no hay consenso sobre cuál es la mejor; sin embargo, el uso de componentes acetabulares de refuerzo como el anillo de Burch-Schneider fue una opción con buenos resultados posoperatorios en este caso
ABSTRACT

Introduction:

Pelvic discontinuity is a complication of total hip arthroplasty, consisting of a structural bone defect of the acetabulum with separation of the upper and lower hemipelvis. Case presentation A 74-year-old male patient with a history of total left hip arthroplasty and 4 arthroplasty revision surgeries visited the emergency department of a secondary care hospital due to pain and limited mobility of the left hip over a period of 7 days after having suffered a fall from his own height in which the left lower limb received the force of the impact. Physical examination showed limitation of the range of motion of the left hip, so a hip X-ray was performed, showing a fracture of the acetabulum. A computed tomography of the hip revealed signs of loosening of the acetabular component and fracture of the acetabulum (type IIIB according to the Paprosky classification). In view of the above, pelvic discontinuity was diagnosed and revision arthroplasty and replacement of the acetabular component with a Burch-Schneider ring was performed. The patient had an adequate postoperative progression and follow-up at 3 months.

Conclusion:

Although there are multiple options for the treatment of pelvic discontinuity, currently, there is no conclusive data regarding the best therapeutic option. However, the use of reinforcement acetabular components, such as the Burch-Schneider ring, was an option with good postoperative outcomes in this case



Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Espanhol Revista: Rev. colomb. ortop. traumatol Assunto da revista: Ortopedia / Traumatologia Ano de publicação: 2023 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Clínica de Especialistas de Sogamoso/CO

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Espanhol Revista: Rev. colomb. ortop. traumatol Assunto da revista: Ortopedia / Traumatologia Ano de publicação: 2023 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Clínica de Especialistas de Sogamoso/CO