Optimización del control interno de calidad de RT-PCR en tiempo real para detección cualitativa de SARS-CoV-2
Torres-Gamarra, Giancarlo.
  • Torres-Gamarra, Giancarlo; s.af
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1535126
RESUMEN

Objetivo:

Optimizar el control interno de calidad de RT-PCR en tiempo real para detección cualitativa de SARS-CoV-2, utilizando los valores Cq de controles negativos y positivos. Material y

método:

Estudio prospectivo-longitudinal. La muestra estuvo constituida por 143 valores Cq para los controles negativos de alicuotado y extracción, así como para el control positivo. Se analizó la distribución normal de los valores Cq mediante la prueba de Anderson-Darling (AD) y se aplicaron pruebas de aleatoriedad. Se calculó límites de control a partir de 51 valores Cq, para luego, mediante gráficas de control, monitorizar 92 valores Cq obtenidos desde noviembre del 2020 hasta marzo del 2021. Se evaluó aceptación de lote e índices Cpk como indicadores de optimización. Los cálculos se hicieron con el programa Minitab.

Resultados:

Se aceptaron los lotes de valores Cq y se obtuvieron índices Cpk superiores a 1.33 para los tres tipos de control.

Discusión:

No existen estudios publicados que apliquen control estadístico de calidad a la detección cualitativa de SARS-CoV-2.

Conclusiones:

Es posible utilizar los valores Cq de los controles para optimizar el control interno de calidad de RT-PCR en tiempo real para detección cualitativa de SARS-CoV-2, como si se tratara de una técnica de tipo cuantitativo.
ABSTRACT

Objective:

To optimize the internal quality control of real-time RT-PCR for the qualitative detection of SARS-CoV-2, using the Cq values ​​of negative and positive controls. Material and

method:

Prospective-longitudinal study. The sample consisted of 143 Cq values for the negative aliquot and extraction controls, as well as for the positive control. The normal distribution of Cq values ​​was analyzed using the Anderson-Darling (AD) test and randomness tests were applied. Control limits were calculated from 51 Cq values, and then, using control charts, to monitor 92 Cq values ​​obtained from November 2020 to March 2021. Lot acceptance and Cpk indices were evaluated as optimization indicators. The calculations were made with the Minitab program.

Results:

The batches of Cq values ​​were accepted and Cpk indices higher than 1.33 were obtained for the three types of control.

Discussion:

There are no published studies that apply statistical quality control to the qualitative detection of SARS-CoV-2.

Conclusions:

It is possible to use the Cq values ​​of the controls to optimize the internal quality control of real-time RT-PCR for qualitative detection of SARS-CoV-2, as if it were a quantitative technique.

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Espanhol Revista: Rev. Cuerpo Méd. Hosp. Nac. Almanzor Aguinaga Asenjo Assunto da revista: Medicina Ano de publicação: 2023 Tipo de documento: Artigo