Your browser doesn't support javascript.
loading
Evaluación de tres pruebas serológicas para la detección de anticuerpos contra el virus linfotrópico T humano tipo 1 (HTLV-1)
Miranda-Ulloa, Eduardo; Romero-Ruiz, Soledad; Valverde-Ticlia, Fanny; Briceño-Espinoza, Ronal; Acuña, Maribel.
  • Miranda-Ulloa, Eduardo; s.af
  • Romero-Ruiz, Soledad; s.af
  • Valverde-Ticlia, Fanny; s.af
  • Briceño-Espinoza, Ronal; s.af
  • Acuña, Maribel; s.af
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1535128
RESUMEN
Introducción: El Perú es endémico al virus linfotrópico T humano tipo 1 (HTLV-1), por esas razones es importante conocer la fiabilidad de las pruebas diagnósticas que se usan en el país, con la finalidad de continuar o no su uso. El objetivo fue evaluar el rendimiento de tres pruebas serológicas ELISA Murex, ELISA Wantai e IFI INS-Perú para la detección de anticuerpos anti HTLV-1 frente a muestras peruanas. El estudio. Las tres pruebas fueron evaluadas frente a 382 sueros: 215 positivos y 167 negativos a HTLV-1 (Gold Standar: inmunoblot). Hallazgos. IFI no presentó falsos positivos, Wantai tuvo más falsos negativos (siete) y Murex más falsos positivos (ocho). Las tres pruebas mostraron resultados superiores a 95% para los parámetros estimados de exactitud diagnóstica. Conclusiones. IFI INS-Perú y ELISA Murex tuvieron buen rendimiento diagnóstico para la detección de anticuerpos contra HTLV-1 y son buenos candidatos para continuar siendo usados en Perú.
ABSTRACT
Background: Peru is endemic to the human T-lymphotropic virus type 1 (HTLV-1), for these reasons it is important to know the reliability of the diagnostic tests used in the country, in order to continue their use or not. The objective was to evaluate the performance of three serological tests ELISA Murex, ELISA Wantai and IFI INS-Peru for the detection of anti-HTLV-1 antibodies against Peruvian samples. The study. The three tests were evaluated against 382 sera: 215 positive and 167 negative for HTLV-1 (Gold Standard: immunoblot). Findings. IFI had no false positives, Wantai had more false negatives (seven) and Murex more false positives (eight). The three tests showed results above 95% for the estimated parameters of diagnostic accuracy. Conclusions. IIF INS-Perú and ELISA Murex had good diagnostic performance for the detection of antibodies against HTLV-1 and are good candidates to continue being used in Peru.

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Espanhol Revista: Rev. Cuerpo Méd. Hosp. Nac. Almanzor Aguinaga Asenjo Assunto da revista: Medicina Ano de publicação: 2023 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Espanhol Revista: Rev. Cuerpo Méd. Hosp. Nac. Almanzor Aguinaga Asenjo Assunto da revista: Medicina Ano de publicação: 2023 Tipo de documento: Artigo