Your browser doesn't support javascript.
loading
Factores de riesgo para falla de la técnica en diálisis peritoneal: estudio de cohorte retrospectivo
Benavides Cruz, Johana; Rubio Romero, Jorge Andrés; Sanabria Arenas, Rafael Mauricio.
  • Benavides Cruz, Johana; s.af
  • Rubio Romero, Jorge Andrés; s.af
  • Sanabria Arenas, Rafael Mauricio; s.af
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1536033
RESUMEN
Contexto la falla de la técnica en diálisis peritoneal puede ocurrir de manera no planificada, afectando los costos en salud y la calidad de vida del paciente. Objetivo estimar la incidencia de falla de la técnica y mortalidad y determinar los factores de riesgo asociados con el tiempo a la falla de la técnica, por causas médicas en el primer año de la terapia de reemplazo renal. Metodología estudio de cohorte retrospectivo que incluyó 2192 pacientes incidentes en diálisis peritoneal, utilizando los registros de centros de terapia renal Baxter en Colombia, durante el periodo entre enero del 2016 y diciembre del 2017. Asimismo, se estimó la tasa de incidencia y la tasa de mortalidad y se usó el análisis de regresión de Cox multivariado para determinar los factores de riesgo para falla de la técnica. Resultados se estimó una tasa de incidencia de falla de la técnica de 8,8/100 personas/año. La tasa de mortalidad fue de 7,9/100 personas/año. El modelo de regresión de Cox multivariado mostró que los factores de riesgo fueron hipertensión arterial (HR 1,59; IC 95 % 1,01-2,48) y género masculino (HR1,62; IC 95 % 1,03-2,56) y los factores protectores fueron el Kt/V > 1,7 (HR 0,41; IC 95 % 0,25-0,65) e incrementar 1 gr/dl la albúmina (HR 0,61; IC 95 % 0,43-0,87). Conclusiones la tasa de incidencia de falla de la técnica en el primer año de diálisis peritoneal en Colombia fue baja y la disfunción mecánica fue la principal causa. Los factores de riesgo asociados con el tiempo a la falla de la técnica fueron hipertensión arterial y género masculino.
ABSTRACT
Background The technique failure in peritoneal dialysis can occur in an unplanned way, affecting health costs and the patient's quality of life. Purpose The aims of this study were to estimate the incidence of technique failure and mortality; and to determine the risk factors associated with time to failure of technique due to medical causes in the first year of renal replacement therapy. Methodology Retrospective cohort study that included 2192 incident patients on peritoneal dialysis using the records of Baxter renal therapy centers in Colombia, during the period January 2016 and December 2017. The incidence rate and mortality rate were estimated. Multivariate Cox regression analysis was used to determine risk factors for technique failure. Results An incidence rate of failure of the technique of 8.8/100 person-years was estimated. The mortality rate was 7.9/100 person-years. The multivariate Cox regression model showed as risk factors arterial hypertension (HR 1.59; 95% CI 1.01-2.48) and male sex (HR 1.62; 95% CI 1.03-2.56); and the protective factors were Kt / V> 1.7 (HR 0.41; CI95% 0.25-0.65) and increase 1 gr / dl of albumin (HR 0.61; CI95% 0.43-0.87). Conclusions The incidence rate of technique failure in the first year of peritoneal dialysis in Colombia was low and mechanical dysfunction was the main cause. The risk factors associated with time to failure of the technique were arterial hypertension and male gender.

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Espanhol Revista: Rev. colomb. nefrol. (En línea) Assunto da revista: Medicina Cl¡nica / Patologia Ano de publicação: 2022 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Espanhol Revista: Rev. colomb. nefrol. (En línea) Assunto da revista: Medicina Cl¡nica / Patologia Ano de publicação: 2022 Tipo de documento: Artigo