Your browser doesn't support javascript.
loading
Resultados iniciais de mundo real do XEN® 45 Gel Stent na população brasileira / Real-world initial results of the XEN® 45 Gel Stent in the Brazilian population
Guedes, Ricardo Augusto Paletta; Guedes, Vanessa Maria Paletta; Gravina, Daniela Marcelo; Moraes, Daniel Augusto Guedes; Chaoubah, Alfredo.
  • Guedes, Ricardo Augusto Paletta; Universidade Federal de Juiz de Fora. Juiz de Fora. BR
  • Guedes, Vanessa Maria Paletta; Instituto de Olhos Paletta Guedes. Juiz de Fora. BR
  • Gravina, Daniela Marcelo; Instituto de Olhos Paletta Guedes. Juiz de Fora. BR
  • Moraes, Daniel Augusto Guedes; Universidade Presidente Antônio Carlos. Barbacena. BR
  • Chaoubah, Alfredo; Universidade Federal de Juiz de Fora. Juiz de Fora. BR
Rev. bras. oftalmol ; 83: e0025, 2024. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1559582
RESUMO
RESUMO Objetivo Avaliar os resultados preliminares em médio prazo (até 6 meses) do uso isolado ou em combinação com a cirurgia de catarata do dispositivo XEN® Gel Stent na população brasileira. Métodos Realizou-se um estudo longitudinal retrospectivo de olhos portadores de glaucoma primário de ângulo aberto consecutivamente submetidos à cirurgia de implante de XEN® Gel Stent isolada (Grupo XEN®) ou em combinação com a cirurgia de catarata (Grupo Faco-XEN®) no mesmo centro entre abril e dezembro de 2023. Analisou-se a capacidade de redução da pressão intraocular e da quantidade de medicamentos hipotensores oculares, além das intercorrências intra e pós-operatórias. O critério de sucesso foi pressão intraocular < 18 mmHg e pelo menos 20% de redução da pressão intraocular pré-operatória (sucesso absoluto sem medicação; sucesso relativo com ou sem medicação). Avaliou-se ainda a duração do procedimento cirúrgico ao longo da curva de aprendizado. Resultados Foram incluídos 37 olhos no estudo (15 no Grupo Faco-XEN® e 22 no Grupo XEN®). A pressão intraocular média reduziu de 19,35 mmHg, no pré-operatório, para 13,05 mmHg, ao fim do acompanhamento (p < 0,001). Já a quantidade de medicamentos caiu de 2,95 para 0,22 por olho, no mesmo período (p < 0,001). A maioria dos pacientes (83%) chegou ao fim do acompanhamento livres de colírios. Não houve diferenças entre os dois grupos em relação à capacidade de redução pressórica e dos colírios. A taxa de sucesso absoluto foi de 81,2 e 86,7% nos Grupos XEN® e Faco-XEN®, respectivamente (p = 0,532). Seis olhos apresentaram falência da bolha e necessitaram de reintervenção cirúrgica. Houve uma redução significativa do tempo de cirurgia ao longo do acompanhamento. Conclusão O dispositivo XEN® Gel Stent foi efetivo, tanto em cirurgia isolada quando combinada, em reduzir a pressão intraocular e a quantidade de medicamentos, com elevado perfil de segurança na população brasileira.
ABSTRACT
ABSTRACT Objective To evaluate the preliminary medium-term results (up to 6 months) of the stand-alone use of XEN® Gel Stent implantation or in combination with cataract surgery in the Brazilian population. Methods A retrospective longitudinal study was carried out on eyes with primary open-angle glaucoma consecutively submitted to XEN® Gel Stent implantation surgery alone (XEN® Group) or in combination with cataract surgery (Phaco-XEN® Group) in the same center between April and December 2023. The ability to reduce intraocular pressure and the amount of ocular hypotensive medications were analyzed, in addition to intra- and postoperative complications. The success criterion was intraocular pressure < 18 mmHg and at least 20% reduction from the preoperative intraocular pressure (absolute success without medication; relative success with or without medication). The duration of the surgical procedure was also evaluated throughout the learning curve. Results Thirty-seven eyes were included in the study (15 in the Phaco-XEN® group and 22 in the XEN® group). The mean intraocular pressure was reduced from 19.35 mmHg preoperatively to 13.05 mmHg at the end of the follow-up (p < 0,001). The amount of medication decreased from 2.95 to 0.22 per eye in the same period (p < 0,001). Of the patients, 83% reached the end of follow-up without no need for eye drops. There were no differences between the two groups in terms of intraocular pressure reduction capacity and eye drops. The absolute success rate was 81.2 and 86.7% in the XEN® and Phaco-XEN® Groups, respectively (p = 0.532). Six eyes presented bleb failure and required surgical reintervention. There was a significant reduction in surgery time throughout follow-up. Conclusion The XEN® gel stent implantation was effective, both in stand-alone and in combined surgery, in reducing intraocular pressure and the medication burden, with a high safety profile in the Brazilian population.


Texto completo: DisponíveL Índice: LILACS (Américas) País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Rev. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2024 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Instituto de Olhos Paletta Guedes/BR / Universidade Federal de Juiz de Fora/BR / Universidade Presidente Antônio Carlos/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Rev. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2024 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Instituto de Olhos Paletta Guedes/BR / Universidade Federal de Juiz de Fora/BR / Universidade Presidente Antônio Carlos/BR