Your browser doesn't support javascript.
loading
Oscilação oral de alta frequência e fibrose cística: comparação entre instrumentais / High-frequency oral oscillation and cystic fibrosis: a comparison between instruments
Suzan, Ana Beatriz Biagioli Manoel; Galvão, Fábio; Ribeiro, Antônio Fernando; Ribeiro, José Dirceu; Ribeiro, Maria Ângela Gonçalves de Oliveira; Assumpção, Maíra Seabra de; Schivinski, Camila Isabel Santos.
  • Suzan, Ana Beatriz Biagioli Manoel; Centro Universitário Nossa Senhora do Patrocínio. Itú. BR
  • Galvão, Fábio; Centro Universitário Nossa Senhora do Patrocínio. Itú. BR
  • Ribeiro, Antônio Fernando; Universidade Estadual de Campinas. Campinas. BR
  • Ribeiro, José Dirceu; Univesidade Estadual de Campinas. Campinas. BR
  • Ribeiro, Maria Ângela Gonçalves de Oliveira; Univesidade Estadual de Campinas. Campinas. BR
  • Assumpção, Maíra Seabra de; Universidade do Estado de Santa Catarina. Florianópolis. BR
  • Schivinski, Camila Isabel Santos; Universidade do Estado de Santa Catarina. Florianópolis. BR
Conscientiae saúde (Impr.) ; 14(2): 283-290, 30 jun. 2015.
Artigo em Português | LILACS | ID: biblio-770
RESUMO

Objetivos:

Avaliar e comparar o efeito do Flutter VRP1® e do Shaker® referente à quantidade de secreção pulmonar expectorada e aos parâmetros cardiorrespiratórios de frequência cardíaca (fc) e de saturação periférica de oxigênio (SpO2).

Método:

Neste estudo randomizado do tipo intervencional, 16 pacientes, com idades entre 7 e 21 anos (12 anos ±4,11), realizaram sessões de fisioterapia em dois dias diferentes com ambos os dispositivos. Na primeira sessão, os participantes utilizaram um dos dispositivos, conforme o resultado da randomização. E, após sete dias sem intervenção, na segunda sessão, usaram o outro dispositivo. Verificaram-se os parâmetros cardiorrespiratórios de fc e SpO2 e registraram-se tais valores antes e ao final de cada coleta em cada dia de terapia. Colheu-se secreção pulmonar durante e após a terapia para determinação dos pesos seco e úmido.

Resultados:

Não houve diferença entre os dispositivos quanto a peso úmido (p=0,589) e seco (p=0,719) e parâmetros cardiorrespiratórios de fc e SpO2.

Conclusão:

Os dispositivos foram semelhantes em relação às variáveis analisadas
ABSTRACT

Objectives:

To evaluate and compare the effect of Flutter VRP1® and Shaker® on the amount of expectorated pulmonary secretions and on heart rate (HR) and peripheral oxygen saturation (SO2) cardiorespiratory parameters.

Method:

In this randomized interventional study, 16 patients, aged between 7 and 21 years (12 years±4.11), performed physiotherapy sessions on two different days with both devices. In the first session, participants used one of the devices, according to the randomization. After seven days without intervention, they underwent a second session with the other device. The cardiorespiratory parameters of HR and SO2 were recorded immediately before and after each session on every day of therapy. The collection of pulmonary secretions was conducted during and after therapy to determine the dry and wet weights.

Results:

There was no difference between the devices as to the wet weight (p=0.589) and dry weight (p=0.719) nor HR and SO2 cardiorespiratory parameters.

Conclusion:

The devices were similar in relation to the analyzed variables.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Terapia Respiratória / Ventilação de Alta Frequência / Fibrose Cística Tipo de estudo: Ensaio Clínico Controlado / Estudo de rastreamento Limite: Adolescente / Adulto / Criança / Feminino / Humanos / Masculino Idioma: Português Revista: Conscientiae saúde (Impr.) Assunto da revista: Medicina / MEDICINA FISICA E REABILITACAO Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário Nossa Senhora do Patrocínio/BR / Universidade Estadual de Campinas/BR / Universidade do Estado de Santa Catarina/BR / Univesidade Estadual de Campinas/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Terapia Respiratória / Ventilação de Alta Frequência / Fibrose Cística Tipo de estudo: Ensaio Clínico Controlado / Estudo de rastreamento Limite: Adolescente / Adulto / Criança / Feminino / Humanos / Masculino Idioma: Português Revista: Conscientiae saúde (Impr.) Assunto da revista: Medicina / MEDICINA FISICA E REABILITACAO Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário Nossa Senhora do Patrocínio/BR / Universidade Estadual de Campinas/BR / Universidade do Estado de Santa Catarina/BR / Univesidade Estadual de Campinas/BR