Your browser doesn't support javascript.
loading
Avaliação da estabilidade dimensional de diferentes marcas de silicone por reação de condensação ­ estudo in vitro / Assessment of the dimensional stability of distinct condensation silicone trademarks ­ an in vitro study
Piculski, Cintia Ligia Olichevis; Berger, Guilherme; Picheth, Guilherme Fadel; Betiol, Ederson Aureo Gonçalves; Hayashida, Marcelo de Freitas.
  • Piculski, Cintia Ligia Olichevis; s.af
  • Berger, Guilherme; UFPR. Jandaia do Sul. BR
  • Picheth, Guilherme Fadel; s.af
  • Betiol, Ederson Aureo Gonçalves; UFPR. Jandaia do Sul. BR
  • Hayashida, Marcelo de Freitas; UTPPR. Curitiba. BR
Prosthes. Lab. Sci ; 6(21): 38-44, 2016. ilus, tab
Artigo em Português | LILACS, BBO | ID: biblio-837401
RESUMO
Na prática odontológica, o vazamento de gesso nos moldes é muitas vezes tardio, e a maioria é enviada ao laboratório para verter o gesso em até 72 horas. Portanto, os profissionais devem ficar cientes do tempo de atraso tolerável para o qual o material de moldagem permanecerá dimensionalmente preciso. O objetivo deste estudo foi avaliar a alteração dimensional de quatro marcas comerciais de silicone por reação de condensação: Speedex (Vigodent)®, Coltex/Coltoflax (Vigodent)®, Clonage (Nova DFL)® e Zetaplus/Oranwash (Zhermack)®, em função de seis diferentes tempos de vazamento de gesso, e sugerir o tempo máximo de armazenagem dos moldes. Para isso, foi confeccionado um modelo mestre com três cilindros metálicos, fixados em região de rebordo alveolar de uma maxila em acrílico, e 12 moldeiras individuais. A técnica de moldagem utilizada foi a do material em consistência densa e fluida em dois estágios. foram obtidos 72 modelos em gesso GC fujirock® EP melhorado tipo IV, os quais foram mensurados com paquímetro digital Mytutoyo®. Os resultados foram comparados ao modelo controle e aplicados ao teste de hipóteses "t de student". Concluiu-se que as marcas comerciais de silicone por reação de condensação Zetaplus® e Clonage® apresentaram modelos experimentais que não diferiram estatisticamente do modelo mestre para todos os tempos estudados. Já as marcas comerciais Coltex Coltoflax® e Speedex® apresentaram-se estatisticamente diferentes ao modelo mestre nos maiores tempos de armazenamento.
ABSTRACT
In dental practice, plaster casting is often late, and most are sent to the laboratory to pour the plaster in up to 72 hours. Therefore professionals should be aware of the tolerable delay time for which the molding material will remain dimensionally accurate. The objective of this study was to evaluate the dimensional alteration of four commercial brands of silicone by condensation reaction, Speedex (Vigodent)®, Coltex / Coltoflax (Vigodent)®,Clonage (Nova DFL)®, Zetaplus / Oranwash (Zhermack)®, in function of six different casting times, and suggest the maximum storage time of the molds. Therefore, a master model with three metal cylinders was made, fixed in the alveolar ridge region of an acrylic jaw, and 12 individual trays. The technique of molding used was that of the material in dense consistency and fluid in two stages. A total of 72 GC fujirock® EP improved plaster models were obtained, which were measured using a Mytutoyo® digital caliper. The results were compared to the control model and the "t student" hypothesis test was applied. It was concluded that the trademarks of silicone by condensation reaction Zetaplus® and Clonage® presented experimental models that did not differ statistically from the master model for all the studied times. Coltex Coltoflax® and Speedex® trademarks were statistically different from the master model in the longest storage times.
Assuntos

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Elastômeros de Silicone / Silicones / Materiais para Moldagem Odontológica / Materiais Dentários / Precisão da Medição Dimensional Limite: Humanos Idioma: Português Revista: Prosthes. Lab. Sci Assunto da revista: Odontologia / Pr¢tese Dent ria Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: UFPR/BR / UTPPR/BR

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Elastômeros de Silicone / Silicones / Materiais para Moldagem Odontológica / Materiais Dentários / Precisão da Medição Dimensional Limite: Humanos Idioma: Português Revista: Prosthes. Lab. Sci Assunto da revista: Odontologia / Pr¢tese Dent ria Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: UFPR/BR / UTPPR/BR