Your browser doesn't support javascript.
loading
Radiation exposure in endovascular infra-renal aortic aneurysm repair and factors that influence it
Machado, Rui; Ferreira, Vitor Miguel Dias; Loureiro, Luis; Gonçalves, João; Oliveira, Pedro; Almeida, Rui.
  • Machado, Rui; Hospital de Santo António. Centro Hospitalar do Porto. Porto. PT
  • Ferreira, Vitor Miguel Dias; Hospital de Santo António. Centro Hospitalar do Porto. Porto. PT
  • Loureiro, Luis; Hospital de Santo António. Centro Hospitalar do Porto. Porto. PT
  • Gonçalves, João; Hospital de Santo António. Centro Hospitalar do Porto. Porto. PT
  • Oliveira, Pedro; Hospital de Santo António. Centro Hospitalar do Porto. Porto. PT
  • Almeida, Rui; Hospital de Santo António. Centro Hospitalar do Porto. Porto. PT
Rev. bras. cir. cardiovasc ; 31(6): 415-421, Nov.-Dec. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-843453
ABSTRACT
Abstract

Objective:

The endovascular repair of aortic abdominal aneurysms exposes the patients and surgical team to ionizing radiation with risk of direct tissue damage and induction of gene mutation. This study aims to describe our standard of radiation exposure in endovascular aortic aneurysm repair and the factors that influence it.

Methods:

Retrospective analysis of a prospective database of patients with abdominal infra-renal aortic aneurysms submitted to endovascular repair. This study evaluated the radiation doses (dose area product (DAP)), fluoroscopy durations and their relationships to the patients, aneurysms, and stent-graft characteristics.

Results:

This study included 127 patients with a mean age of 73 years. The mean DAP was 4.8 mGy.m2, and the fluoroscopy time was 21.8 minutes. Aortic bilateral iliac aneurysms, higher body mass index, aneurysms with diameters larger than 60 mm, necks with diameters larger than 28 mm, common iliac arteries with diameters larger than 20 mm, and neck angulations superior to 50 degrees were associated with an increased radiation dose. The number of anatomic risk factors present was associated with increased radiation exposure and fluoroscopy time, regardless of the anatomical risk factors.

Conclusion:

The radiation exposure during endovascular aortic aneurysm repair is significant (mean DAP 4.8 mGy.m2) with potential hazards to the surgical team and the patients. The anatomical characteristics of the aneurysm, patient characteristics, and the procedure's technical difficulty were all related to increased radiation exposure during endovascular aortic aneurysm repair procedures. Approximately 40% of radiation exposure can be explained by body mass index, neck angulation, aneurysm diameter, neck diameter, and aneurysm type.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Doses de Radiação / Aneurisma da Aorta Abdominal / Exposição à Radiação / Procedimentos Endovasculares Tipo de estudo: Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Inglês Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Portugal Instituição/País de afiliação: Hospital de Santo António/PT

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Doses de Radiação / Aneurisma da Aorta Abdominal / Exposição à Radiação / Procedimentos Endovasculares Tipo de estudo: Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Inglês Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Portugal Instituição/País de afiliação: Hospital de Santo António/PT