Ventilação não invasiva na capacidade funcional de cardiopatas com fração de ejeção ventricular normal / Noninvasive ventilation in functional capacity of cardiac patients with normal fraction ventricular ejection
Silva, Joelson dos Santos; Cavalcante, Ananília Regina Silva; Medeiros, Nathalie Cortez Bezerra de; Gonçalves, Carolina Taveira; Lopes, Johnnatas Mikael; Mont'Alverne, Daniela Gardano Bucharles; Christofoletti, Gustavo; Magnani, Karla Luciana.
  • Silva, Joelson dos Santos; Universidade Federal do Rio Grande do Norte. Natal. BR
  • Cavalcante, Ananília Regina Silva; Faculdade de Ciências da Saúde do Trairi. Santa Cruz. BR
  • Medeiros, Nathalie Cortez Bezerra de; Universidade Federal do Rio Grande do Norte. Natal. BR
  • Gonçalves, Carolina Taveira; Faculdade de Ciências da Saúde do Trairi. Santa Cruz. BR
  • Lopes, Johnnatas Mikael; Universidade Federal do Rio Grande do Norte. Natal. BR
  • Mont'Alverne, Daniela Gardano Bucharles; Universidade Federal do Ceará. Fortaleza. BR
  • Christofoletti, Gustavo; Universidade Federal de Mato Grosso do Sul. Campo Grande. BR
  • Magnani, Karla Luciana; Universidade Federal de Mato Grosso do Sul. Campo Grande. BR
Conscientiae saúde (Impr.) ; 15(4): 584-592, 30 dez. 2016.
Artigo em Português | LILACS | ID: biblio-846731
RESUMO

Introdução:

A insuficiência cardíaca (IC) é um problema de saúde pública com altos níveis de morbimortalidade apresentando como sinais clínicos característicos a fadiga e dispneia precoce que geram limitações funcionais.

Objetivo:

Avaliar os efeitos da ventilação não invasiva (VNI) na capacidade funcional de portadores de insuficiência cardíaca estável com fração de ejeção normal, avaliada através do teste da caminhada de seis minutos em esteira (TC6est).

Métodos:

Após a avaliação das provas de função pulmonar, os pacientes com IC estudados foram submetidos aos seguintes testes 3 TC6est (uso prévio da VNI por 30 minutos, com uso da VNI durante o teste e sem uso da VNI) e a um teste de caminhada de 6 minutos em solo (TC6'). Nós comparamos a distância percorrida e variáveis cardiorrespiratórias antes, durante e após os testes da caminhada.

Resultados:

Participaram do estudo 13 pacientes com IC classe funcional II e III (NYHA). Na prova de função pulmonar 3 participantes apresentaram distúrbio ventilatório restritivo e 8 pacientes apresentaram redução das pressões respiratórias máximas. Não foi observada diferença estatisticamente significativa na distância percorrida entre os quatro testes realizados (p=0,986). Na análise das variáveis cardiorrespiratórias durante os 3 TC6est pôde-se observar apenas diferença estatística significativa na frequência respiratória no sexto minuto (f6') entre os testes de 30' antes de VNI X VNI durante (p=0,026), sendo inferior no teste com a aplicação de VNI durante.

Conclusão:

Apesar do comprometimento da capacidade funcional e da função pulmonar, os portadores de insuficiência cardíaca com fração de ejeção normal estudados não tiveram aumento da distância percorrida no teste de caminhada em esteira com a utilização do suporte ventilatório não­invasivo.
ABSTRACT

Introduction:

Heart failure (HF) is a public health problem with high morbidity levels and mortality, presenting fatigue and early dyspnea as clinical signs characteristic that generate functional limitations.

Objective:

To evaluate the noninvasive ventilation (NIV) effects in functional capacity of patients with stable heart failure with a normal ejection fraction, evaluated using six-minute treadmill walk (tread- 6MWT).

Method:

After pulmonary function tests evaluation, the patients with HF studied were submitted to the following tests 3 tread6MWT (previous use of NIV for 30 minutes, use of NIV during the test and without use of NIV) and one test 6-minute test soil (6MWT). They compared the walking distance (WD) and cardiorespiratory variables before, during and after the walking tests.

Results:

13 patients with class II and III HF (NYHA) participated in the study. In the pulmonary function test, 3 participants presented restrictive ventilatory disorder and 8 patients had a reduction in maximum respiratory pressures. There was no statistically significant difference in distance between the four tests performed (p = 0.986). In the analysis of the cardiorespiratory variables during the 3 tread6MWT, only a significant statistical difference in the respiratory rate in the sixth minute (f6 ') between the tests 30' before NIV X NIV during (p =0.026) was observed, being lower in the test with the application of NIV during the test.

Conclusion:

Despite the functional capacity impairment and lung function, patients with heart failure with normal ejection fraction studied did not increase the distance walked on the treadmill treadmill test with non-invasive ventilatory support.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Capacidade Residual Funcional / Insuficiência Cardíaca Diastólica Limite: Idoso / Feminino / Humanos / Masculino Idioma: Português Revista: Conscientiae saúde (Impr.) Assunto da revista: Medicina / MEDICINA FISICA E REABILITACAO Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade de Ciências da Saúde do Trairi/BR / Universidade Federal de Mato Grosso do Sul/BR / Universidade Federal do Ceará/BR / Universidade Federal do Rio Grande do Norte/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Capacidade Residual Funcional / Insuficiência Cardíaca Diastólica Limite: Idoso / Feminino / Humanos / Masculino Idioma: Português Revista: Conscientiae saúde (Impr.) Assunto da revista: Medicina / MEDICINA FISICA E REABILITACAO Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade de Ciências da Saúde do Trairi/BR / Universidade Federal de Mato Grosso do Sul/BR / Universidade Federal do Ceará/BR / Universidade Federal do Rio Grande do Norte/BR