Your browser doesn't support javascript.
loading
Effect of blood contamination during adhesive restorative procedures on dentin-resin cement shear bond strength
Soares, Carlos José; Branco, Carolina Assaf; Soares, Priscilla Barbosa Ferreira; Fonseca, Rodrigo Borges; Carlo, Hugo Lemes; Fernandes Neto, Alfredo Júlio.
  • Soares, Carlos José; Federal University of Uberlândia. Dental School. Department of Operative Dentistry and Dental Materials. Uberlândia. BR
  • Branco, Carolina Assaf; Federal University of Uberlândia. Dental School. Department of Occlusion and Fixed Prosthodontics. Uberlândia. BR
  • Soares, Priscilla Barbosa Ferreira; Federal University of Uberlândia. Dental School. Department of Operative Dentistry and Dental Materials. Uberlândia. BR
  • Fonseca, Rodrigo Borges; Federal University of Uberlândia. Dental School. Department of Operative Dentistry and Dental Materials. Uberlândia. BR
  • Carlo, Hugo Lemes; Federal University of Uberlândia. Dental School. Department of Operative Dentistry and Dental Materials. Uberlândia. BR
  • Fernandes Neto, Alfredo Júlio; Federal University of Uberlândia. Dental School. Department of Occlusion and Fixed Prosthodontics. Uberlândia. BR
Braz. j. oral sci ; 6(21): 1320-1325, Apr.-June 2007. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: biblio-850533
ABSTRACT
The aim of this study was to evaluate the effect of dentin blood contamination during different steps of the restorative procedure on resin cement shear bond strength to dentin. Crows of 120 bovine incisors were prepared to obtain flat superficial dentin surfaces. Dentin was etched with phosphoricacid and contaminated with fresh blood for 10 seconds, before or after adhesive system application. Different treatments were tested in contaminated dentin, resulting on eight groups (N=15). Composite resin restorations (TPH Spectrum, Dentsply) were adhesively fixed (Excite, Ivoclar-Vivadent) withresin cement (Variolink 2, Ivoclar-Vivadent) and shear bond strength test (0.5 mm/min) was performed. Morphologic observations were carried out with scanning electron microscopy (SEM). Data (MPa) were submitted to one-way ANOVA following Tukey's test (p<0.05), showing that blood contamination during adhesive procedure negatively affects bond strength, and decontamination methods do not recover original bond strength. The negative effects of bloodcontamination on shear bond strength to dentin and resin cement were significant in all contaminated groups; none of the tested dentin treatment procedures resulted in higher bond strength irrespective of the moment on which blood contamination took place.
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Sangue / Adesivos Dentinários / Resistência ao Cisalhamento / Dentina / Poluição Ambiental Limite: Animais Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Uberlândia/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Sangue / Adesivos Dentinários / Resistência ao Cisalhamento / Dentina / Poluição Ambiental Limite: Animais Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Uberlândia/BR