Your browser doesn't support javascript.
loading
Dilatación de la raíz aórtica en pacientes con válvula bicúspide tras la sustitución valvular aórtica / Dilatation of the aortic root in patients with bicuspid valve after aortic valve replacement
Dayan, Victor; Cura, Leandro; Pizzano, Nelson; Muñoz, León; Michelis, Virginia; Dominguez, Enrique; Soca, Gerardo; Ferreiro, Alejandro.
  • Dayan, Victor; Instituto Nacional de Cirugía Cardiaca. Facultad de Medicina. Hospital de Clínicas. Montevideo. UY
  • Cura, Leandro; Instituto Nacional de Cirugía Cardiaca. Facultad de Medicina. Hospital de Clínicas. Montevideo. UY
  • Pizzano, Nelson; Instituto Nacional de Cirugía Cardiaca. Facultad de Medicina. Hospital de Clínicas. Montevideo. UY
  • Muñoz, León; Instituto Nacional de Cirugía Cardiaca. Facultad de Medicina. Hospital de Clínicas. Montevideo. UY
  • Michelis, Virginia; Instituto Nacional de Cirugía Cardiaca. Facultad de Medicina. Hospital de Clínicas. Montevideo. UY
  • Dominguez, Enrique; Instituto Nacional de Cirugía Cardiaca. Facudad medicina. Hospital de Clínicas. Montevideo. UY
  • Soca, Gerardo; Instituto Nacional de Cirugía Cardiaca. Centro Cardiovascular. Hospital de Clinicas. Montevideo. UY
  • Ferreiro, Alejandro; Instituto Nacional de Cirugía Cardiaca. Centro Cardiovascular. Hospital de Clínicas. Montevideo. UY
Rev. guatem. cardiol. (Impresa) ; 24(1): 6-11, ene.-jun. 2014. tab
Artigo em Espanhol | LILACS | ID: biblio-869903
RESUMEN
Introducción y

objetivos:

La válvula aórtica bicúspide (VAB) esta vinculada con la patología aórtica.Pacientes con VAB tienen elevada probabilidad de requerir cirugía debido a dilatación aórtica o afectaciónvalvular. La progresión en la dilatación aortica luego de la sustitución de la válvula aórtica (SVA), no se haevaluado forma definitoria.

Métodos:

Un total de 23 pacientes con VAB y diámetro de la raíz aortica inferior a45 mm fueron seguidos durante una media de 8 años luego de la SVA. La medición ecocardiográfica de laraíz aórtica y la aorta tubular se realizó a los 6 y 8 años de la cirugía. Se determinaron predictores dedilatación.

Resultados:

La raíz aórtica entre 6 (34,6 ± 7,4 mm) y 8 años (37,6 ± 7,7 mm) de seguimientoincrementó significativamente (p <0,023), no se encontraron diferencias con la aorta tubular. La dilatación seobservó principalmente entre fumadores, con antecedentes familiares y dislipémia. Los factores predictorespara dilatación de la raíz aórtica fueron antecedentes familiares de VAB o patología aórtica, tamaño de laprótesis y superficie corporal (SC). El análisis de regresión multivariado evidenció solo la SC y antecedentesfamiliares como predictores significativos.

Conclusión:

La raíz aórtica continúa dilatándose tras la SVA enpacientes con VAB. La SC y la historia familiar de patología aórtica, son fuertes predictores de dilatación de laraíz aórtica. Estos pacientes deben ser seguidos de cerca luego de la SVA.
ABSTRACT

Background:

Bicuspid aortic valve (BAV) has been closely correlated with aortic pathology. BAV patientshave a high probability of being operated along their lifetime for aortic disease. Progression of aortic dilatationafter aortic valve replacement (AVR) has not being definitely assessed.

Methods:

A total of 23 BAV withaortic diameter ≤ 45mm patients were followed for a mean of 8 years after AVR. Echocardiographicmeasurement of the aortic root and tubular aorta was done after a mean of 6 and 8 years post-operatively.Predictors for dilatation were estimated.

Results:

Paired comparison of aortic root diameter between 6(34.6±7.4 mm) and 8 years (37.6±7.7 mm) of follow-up showed that its dimension increased significantly(p<0.023) while no differences were found with the tubular aorta. Dilatation was seen mainly in smokers,family history and dyslipemic patients. Univariate predictors for aortic root dilatation were family history ofBAV or aortic pathology, prosthesis size and body surface area (BSA). Multivariate regression evidenced onlyBSA (beta coefficient 11.5) and family history (beta coefficient 4.5) as significant predictors.

Conclusion:

Aortic root continues to dilate after AVR in BAV patients. Higher BSA and family history of aortic pathologywere found as strong predictors of aortic root dilatation. These patients should be closely followed after AVR.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Valva Aórtica / Cardiopatias Congênitas / Valva Mitral Tipo de estudo: Estudo prognóstico Limite: Humanos Idioma: Espanhol Revista: Rev. guatem. cardiol. (Impresa) Assunto da revista: Cardiologia / Medicina Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Uruguai Instituição/País de afiliação: Instituto Nacional de Cirugía Cardiaca/UY

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Valva Aórtica / Cardiopatias Congênitas / Valva Mitral Tipo de estudo: Estudo prognóstico Limite: Humanos Idioma: Espanhol Revista: Rev. guatem. cardiol. (Impresa) Assunto da revista: Cardiologia / Medicina Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Uruguai Instituição/País de afiliação: Instituto Nacional de Cirugía Cardiaca/UY