Your browser doesn't support javascript.
loading
Influência do laser de baixa potência (GaAlAs-lambda830nm) na formação óssea em relação à estabilidade primária em osso tipo IV / Influence of low power laser (GaAlAs-lambda830nm) on bone formation related to primary stability in type IV bone
Torres, Marco Antônio Rambo Osório; Teixeira, Eduardo Rolim.
  • Torres, Marco Antônio Rambo Osório; ABO-RS. EAP. Porto Alegre. BR
  • Teixeira, Eduardo Rolim; PUCRS. Programa de Pós-Graduação em Odontologia. Porto Alegre. BR
Rev. odonto ciênc ; 23(2): 175-181, abr.-jun. 2008. ilus, tab
Artigo em Português | LILACS, BBO | ID: biblio-873595
RESUMO

Objetivo:

Este trabalho in vivo com histomorfometria post mortem avaliou a influência do laser de baixa potência na formação óssea em implantes em relação à estabilidade primária em osso tipo IV.

Metodologia:

Seis coelhos da raça Nova Zelândia receberam quatro implantes cada, dois com ancoragem monocortical e dois com bicortical na tíbia. O grupo experimental recebeu irradiação com laser de GaAlAs - λ830nm em três pontos ao redor dos implantes, durante 15 dias a cada 48h, totalizando 24J/cm2 por tíbia. A rotina do grupo controle foi idêntica, porém com o equipamento desligado. Após 30 dias todos os animais sofreram eutanásia. Obtiveram-se lâminas histológicas para avaliação do percentual de contato osso-implante (%COI).

Resultados:

Não houve diferença estatisticamente significativa (teste t-Student, P>0,05) entre os grupos laser e controle com ancoragem mono (73%±9 e 62%±15) ou bicortical (81%±10 e 77%±21). A histomorfometria sugeriu que o efeito do laser no %COI foi mais positivo nos implantes com menor estabilidade primária. As amostras irradiadas pareceram apresentar maior vascularização e organização lamelar, sugerindo maior maturação em relação ao controle, independente da estabilidade.

Conclusão:

O laser não mostrou efeito estatisticamente significativo na %COI. Não obstante, a maior diferença numérica entre o grupo laser e o grupo controle sempre ocorreu nos implantes inseridos com menor estabilidade primária.
ABSTRACT

Purpose:

This in vivo study using post mortem histomorphometrical analysis evaluated the influence of low power laser on bone formation around implants related to primary stability in type IV bone.

Methods:

Six white New Zealand rabbits received four implants each two with monocortical anchorage and two with bicortical anchorage, in tibia-bones. The laser group was irradiated with GaAIAs - λ830nm laser in three points around the implants, at 48-hour intervals during 15 days, with a 24J/cm2 treatment dose per tibia. The control group was subjected to the same routine but the laser equipment was turned off. After 30 days all animals were subjected to euthanasia. Histological sections were obtained to evaluate the percentage of bone-to-implant contact (%COI).

Results:

No statistically significant difference (Student t-test, P>0.05) was found between laser and control groups for either monocortical anchorage (73%±9 and 62%±15) or bicortical anchorage (81%±10 and 77%±21). The histomorphometrical analysis suggested that laser might improve %COI in implants with lower primary stability. The irradiated group presented greater vascular and lamellar organization, suggesting higher maturation than the control group, independently from stability.

Conclusion:

Laser application had no significant effect on % COI. However, the largest difference between laser and control groups always occurred in implants with lower primary stability.
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Implantes Dentários / Terapia com Luz de Baixa Intensidade Limite: Animais Idioma: Português Revista: Rev. odonto ciênc Assunto da revista: Odontologia Ano de publicação: 2008 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: ABO-RS/BR / PUCRS/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Implantes Dentários / Terapia com Luz de Baixa Intensidade Limite: Animais Idioma: Português Revista: Rev. odonto ciênc Assunto da revista: Odontologia Ano de publicação: 2008 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: ABO-RS/BR / PUCRS/BR