Avaliação da alteração dimensional de quatro marcas comerciais de silicone por reação de adição variando o tempo de armazenagem dos moldes / Dimensional alteration assessment of four silicone brands through addition reaction varying molds storage time
Prosthes. Esthet. Sci
;
7(26): 64-70, 20180100. ilus, tab
Artigo
em Português
| LILACS, BBO
| ID: biblio-885147
RESUMO
O objetivo deste estudo foi mensurar e comparar a precisão dimensional de modelos de gesso confeccionados por meio de moldagem de impressão única (material pesado/fluído de uma única vez) com quatro diferentes marcas comerciais de silicone polimerizados por reação de adição (Express XT®, Futura®, Aquasil® e Virtual®). Inicialmente, foi confeccionado um modelo acrílico mestre, o qual possuía três pilares metálicos paralelos entre si e equidistantes 50 mm um do outro. Para obtenção dos moldes foram utilizadas cinco moldeiras individuais em acrílico, cujas faces externas adaptavam-se perfeitamente na base do modelo padrão, promovendo o "stop" de inserção da moldeira. Após o procedimento de moldagem e confecção dos modelos experimentais, foram medidas as distâncias entre os três cilindros e o diâmetro de cada cilindro. Essas medições foram feitas por três vezes em um mesmo ponto e, destas, criou-se uma média obtendo os resultados finais. Os valores das distâncias foram analisados estatisticamente por meio de uma análise bifatorial, e as médias comparadas pelo teste de Tukey (5%). Os dados demostraram que todas as marcas analisadas apresentaram alteração dimensional e diferiram entre si quando comparadas.
ABSTRACT
The objective of this study was to measure and compare the dimensional accuracy of plaster models made by only impression molding (heavy material/fluid at one time) of four different brands of polymerized silicone through addition reaction (Express XT®, Futura ®, Aquasil® and Virtual®). Initially, a master acrylic model was manufactured, which had three parallel metal pillars and equidistant 50 mm from each other. To obtain the impressions, we used five individual acrylic trays, whose external faces perfectly adapted to the standard model base, thus promoting the "stop" of molding insertion. Following the molding procedure and the experimental models manufacturing, distances between the three cylinders and the diameter of each cylinder were measured. These measurements were made three times at the same point, and from these average results were obtained. The distance values were statistically analyzed using a two-factor analysis and the means compared by Tukey test (5%). The data demonstrated that all the analyzed brands presented dimensional changes and differed from each other when compared.
Buscar no Google
Índice:
LILACS (Américas)
Assunto principal:
Elastômeros de Silicone
/
Silicones
/
Sulfato de Cálcio
/
Materiais para Moldagem Odontológica
/
Precisão da Medição Dimensional
Tipo de estudo:
Estudo prognóstico
Limite:
Humanos
Idioma:
Português
Revista:
Prosthes. Esthet. Sci
Assunto da revista:
Odontologia
/
Pr¢tese Dent ria
Ano de publicação:
2018
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
UFPR/BR
Similares
MEDLINE
...
LILACS
LIS