End-to-side versus end-to-end neurorrhaphy at the peroneal nerve in rats
Acta cir. bras
;
32(9): 697-705, Sept. 2017. tab, graf
Artigo
em Inglês
| LILACS
| ID: biblio-886238
ABSTRACT
Abstract Purpose:
To evaluate three different kinds of neurorrhaphy of the peroneal nerve.Methods:
Eigthy rats were divided into 5 groups. Control nerve had no intervention. End-to-end (EE) nerve was cut and elongated with a nerve graft with two end-to-end neurorrhaphies. End-to-side (ES) nerve was cut and sutured to the graft with at the lateral side of the nerve. Side-to-end (SE) the nerve was cut and sutured to the graft with end-to-end neurorrhaphy. Denervated nerve was cut and both endings were buried into the muscle. The evaluation was done by walking track analysis, electrophysiology, body mass, cranial tibial muscle mass, nerve and muscle fibers morphometry.Results:
The EE, ES and SE have the same potential of reinnervation.Conclusion:
There is no functional or histological difference between these different types of neurorrhaphy.
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Nervo Fibular
/
Regeneração Nervosa
Limite:
Animais
Idioma:
Inglês
Revista:
Acta cir. bras
Assunto da revista:
Cirurgia Geral
/
Procedimentos Cir£rgicos Operat¢rios
Ano de publicação:
2017
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
Universidade Estadual Paulista/BR
Similares
MEDLINE
...
LILACS
LIS