Your browser doesn't support javascript.
loading
Luxación de una prótesis abisagrada de rodilla: Reporte de un caso / Posterior dislocation of a hinged knee prosthesis. Case report
Gómez, Diego J; Garabano, Germán; Senes, Sebastián; Pesciallo, César A.
  • Gómez, Diego J; Hospital Británico de Buenos Aires. Servicio de Ortopedia y Traumatología. Ciudad Autónoma de Buenos Aires. AR
  • Garabano, Germán; Hospital Británico de Buenos Aires. Servicio de Ortopedia y Traumatología. Ciudad Autónoma de Buenos Aires. AR
  • Senes, Sebastián; Hospital Británico de Buenos Aires. Servicio de Ortopedia y Traumatología. Ciudad Autónoma de Buenos Aires. AR
  • Pesciallo, César A; Hospital Británico de Buenos Aires. Servicio de Ortopedia y Traumatología. Ciudad Autónoma de Buenos Aires. AR
Rev. Asoc. Argent. Ortop. Traumatol ; 82(4): 294-298, dic. 2017. []
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-896271
RESUMEN
Las prótesis abisagradas de rodilla tienen índices de complicaciones que pueden llegar al 44% en 15 años. La luxación protésica secundaria a una ruptura del mecanismo abisagrado resulta ser la complicación alejada más frecuente luego del aflojamiento mecánico. Presentamos un caso de luxación protésica posterior, en un implante abisagrado rotatorio de tercera generación (Rotax, FII SA®, Saint Just Malmont, Francia), implantado originalmente en una paciente de 69 años, con artritis reumatoide y en terapia prolongada con metilprednisona y metotrexato a altas dosis. El tratamiento se realizó en ambas rodillas, en dos tiempos para corregir una deformidad en ráfaga altamente invalidante. Nuestra hipótesis postula que la luxación se debió a la ruptura del buje de polietileno del implante, este es el eslabón más débil del mecanismo abisagrado. Existen escasos reportes bibliográficos sobre esta particular complicación. Sin embargo, encontramos homogeneidad en las conclusiones, que consideran el ensamble entre el componente tibial y femoral, como el punto más frágil del sistema. Recomendamos, en estos complejos escenarios, efectuar la revisión protésica solo ante la presencia de episodios clínicos evidenciables, como luxaciones o inestabilidad persistente. Nivel de Evidencia IV
ABSTRACT
Hinged knee prosthesis has a complication rate up to 44% at 15 years. Prosthetic dislocation secondary to a breakage of the hinged mechanism turns to be the second most frequent late complication after mechanical loosening. We present a patient with a posterior dislocation of a third generation rotating hinged total knee replacement (Rotax, FII SA®, Saint Just Malmont, France), implanted originally in a 69-year-old woman with rheumatoid arthritis and history of treatment with metilprednisone and methotrexate at high doses. The bilateral arthroplasty was performed in two times to correct a highly disabling deformity. We hypothesize the dislocation is due to the breakage of the polyethylene yoke of the prosthesis, being the weakest link of the hinged mechanism. There are rare bibliographic reports about this complication. However, we found similar conclusions, considering the engage of the tibial and femoral components as the weakest link of the system. We recommend in these complex scenarios to perform revision surgery only in cases with high repercussion in daily life presenting persistent instability or multiple dislocations. Level of Evidence IV
Assuntos

[]

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Falha de Prótese / Luxação do Joelho / Prótese do Joelho Limite: Idoso Idioma: Espanhol Revista: Rev. Asoc. Argent. Ortop. Traumatol Assunto da revista: Ortopedia Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Argentina Instituição/País de afiliação: Hospital Británico de Buenos Aires/AR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Falha de Prótese / Luxação do Joelho / Prótese do Joelho Limite: Idoso Idioma: Espanhol Revista: Rev. Asoc. Argent. Ortop. Traumatol Assunto da revista: Ortopedia Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Argentina Instituição/País de afiliação: Hospital Británico de Buenos Aires/AR