Your browser doesn't support javascript.
loading
Seguridad y eficacia a corto plazo del cierre de orejuela izquierda con dispositivo WATCHMAN ® en fibrilación auricular no valvular en pacientes con alto riesgo de sangrado / Short-term safety and efficacy of left atrial appendage closure using WATCHMAN ® device for non-valvular atrial fibrillation in patients with a high risk of bleeding
Fernández, Andrés; Rodríguez, Arturo; Manuel Sénior, Juan; Aldana, Víctor; Borja, Henry.
  • Fernández, Andrés; Hospital Universitario San Vicente Fundación. Medellín. CO
  • Rodríguez, Arturo; Hospital Universitario San Vicente Fundación. Medellín. CO
  • Manuel Sénior, Juan; Hospital Universitario San Vicente Fundación. Medellín. CO
  • Aldana, Víctor; Hospital Universitario San Vicente Fundación. Medellín. CO
  • Borja, Henry; Hospital Universitario San Vicente Fundación. Medellín. CO
Rev. colomb. cardiol ; 24(4): 369-375, jul.-ago. 2017. tab
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-900547
RESUMEN
Resumen

Objetivo:

Evaluar la seguridad y eficacia del cierre percutáneo de la orejuela izquierda en pacientes con fibrilación auricular no valvular con alto riesgo de sangrado o con contraindicación para anticoagulación oral.

Métodos:

Estudio prospectivo no aleatorizado en una cohorte de pacientes con fibrilación auricular con contraindicación o dificultades con anticoagulación oral y puntaje de CHA2DS2-VASc ≥ 2 y de HASBLED ≥ 2, elegibles para doble antiagregación con aspirina y clopidogrel.

Resultados:

Se incluyeron 53 pacientes, con edad promedio de 72,24 ± 9,22 años, de los cuales 54,72% eran hombres; 20,75% tenían fibrilación auricular paroxística, 15,1% persistente y 64,15% permanente. Además, 18,9% tenían insuficiencia cardíaca, 22,64% enfermedad coronaria, 92,45% hipertensión arterial, 41,51% eran mayores de 75 años, 18,9% eran diabéticos y 37,7% tenían enfermedad cerebrovascular previa. El promedio del puntaje de CHADS2 y CHA2DS2-VASc fue de 2,73 ± 1,34 y 4,24 ± 1,54, respectivamente. El procedimiento fue exitoso en un 98% (52/53). Sólo en un caso no fue posible implantar el dispositivo por causas anatómicas. No hubo eventos adversos serios relacionados con la implantación; durante el procedimiento se registró un episodio de derrame pericárdico leve que no requirió drenaje. En los 45 días de seguimiento, 2 pacientes (3,77%) desarrollaron enfermedad cerebrovascular y se registró un deceso por causa no cardíaca (1,89%).

Conclusiones:

El cierre percutáneo de la orejuela izquierda con dispositivo WATCHMAN® es un procedimiento seguro y eficaz en pacientes de alto riesgo con fibrilación auricular no valvular y contraindicación o dificultades para la anticoagulación oral.
ABSTRACT
Abstract Motivation To assess the safety and efficacy of percutaneous left atrial appendage closure in patients with non-valvular atrial fibrillation with a high risk of bleeding or a contraindication to oral anticoagulation drugs.

Methods:

Prospective non-randomised study of a cohort of patients with atrial fibrillation who had a contraindication to or difficulties with oral anticoagulation, CHA2DS2-VASc ≥ 2 and HASBLED ≥ 2 scores, and who were eligible for dual antiaggregation therapy with aspirin and clopidogrel.

Results:

53 patients with an average age of 72.24 ± 9.22 years were included, out of whom 54.72% were men, 20.75% had paroxysmal, 15.1% persistent and 64.15% permanent atrial fibrillation, respectively. Besides, 18.9% suffered from heart failure, 22.64% from coronary disease, 92.45% from arterial hypertension, 41.51% were over 75 years old, 18.9% were diabetic and 37.7% had a history of cerebrovascular disease. Average CHADS= y CHA=DS2-VASc scores were of 2.73 ± 1.34 and 4.24 ± 1.54 respectively. Procedure was successful in 98% of the cases (52/53). It was not possible to implant the device in only one case due to anatomical reasons. There were no severe adverse events related to the insertion; during the procedure an episode of mild pericardial effusion that did not require drainage was registered. DUring the 45-day follow up period, 2 patients (3.77%) developed a cerebrovascular disease, and there was one noncardiac death (1.89%).

Conclusions:

The percutaneous left atrial appendage closure with device is a safe and efficient procedure in high-risk patients with non-valvular atrial fibrillation and contraindications to or difficulties for oral anticoagulation therapy.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Fibrilação Atrial / Doenças Arteriais Cerebrais Tipo de estudo: Ensaio Clínico Controlado / Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Idoso / Humanos / Masculino Idioma: Espanhol Revista: Rev. colomb. cardiol Assunto da revista: Cardiologia Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Hospital Universitario San Vicente Fundación/CO

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Fibrilação Atrial / Doenças Arteriais Cerebrais Tipo de estudo: Ensaio Clínico Controlado / Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Idoso / Humanos / Masculino Idioma: Espanhol Revista: Rev. colomb. cardiol Assunto da revista: Cardiologia Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Hospital Universitario San Vicente Fundación/CO