Your browser doesn't support javascript.
loading
El glaucoma maligno / Malignant glaucoma
Hernández Pardines, Fernando; Aguirre Balsalobre, Fernando José; Urcola Carrera, Javier Aritz; Alcocer Yuste, Pablo.
Afiliação
  • Hernández Pardines, Fernando; Hospital Universitario de San Juan de Alicante. ES
  • Aguirre Balsalobre, Fernando José; Hospital Universitario de San Juan de Alicante. ES
  • Urcola Carrera, Javier Aritz; Hospital Donostia San Sebastian. ES
  • Alcocer Yuste, Pablo; Fisabio-Oftalmología-Médica (FOM). Valencia. ES
Rev. cuba. oftalmol ; 30(1): 0-0, ene.-mar. 2017. ilus
Article em Es | LILACS | ID: biblio-901346
Biblioteca responsável: CU1.1
RESUMEN
El glaucoma maligno es una forma rara de glaucoma, que suele seguir a la cirugía en pacientes con ángulo cerrado y glaucoma primario de ángulo cerrado. En esta revisión bibliográfica se discuten las características clínicas, la clasificación, la patogenia y el manejo de esta afección. La revisión bibliográfica la efectuamos a partir de una búsqueda en Medline (los principales artículos de PubMed y en Internet) y bases Cochrane (The Cochrane Library). Las imágenes aportadas son propias y las hemos efectuado con tomografía de coherencia óptica SS-1000 de segmento anterior CASIA de Tomey ®. El objetivo de la revisión es revisar las evidencias sobre una afección rara y actualizar los protocolos diagnósticos y terapéuticos con las nuevas técnicas a nuestro alcance. Consideramos que el nombre de glaucoma maligno para esta patología debería evitarse, ya que actualmente con los medios disponibles el pronóstico es relativamente bueno. Es por esto, que preferimos nombres como el síndrome de misdirección del humor acuoso, o glaucoma por bloqueo ciliar(AU)
ABSTRACT
Malignant glaucoma is a rare form of glaucoma that typically follows surgery in patients with primary angle closure and primary angle-closure glaucoma. In this bibliographic review we discuss the clinical characteristics, classification, pathogenesis, and management. The literature review is based on a search in Medline (the main articles of PubMed, Internet) and Cochrane databases (The Cochrane Library). The images provided we have done them with SS-1000 Optical Coherence Tomography CASIA of Tomey ®. The aim of the review is to review the evidence for a rare condition and update the diagnostic and therapeutic protocols with the new techniques. In addition, the review authors thought that the name of malignant glaucoma for this pathology should be avoided, because of prognosis is relatively good. This is the reason, we prefer names such as misdirected aqueous humor syndrome, or ciliary blockage glaucoma(AU)
Assuntos
Palavras-chave
Texto completo: 1 Índice: LILACS Assunto principal: Literatura de Revisão como Assunto / Glaucoma de Ângulo Fechado / Bases de Dados Bibliográficas / Tomografia de Coerência Óptica Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: Es Revista: Rev. cuba. oftalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2017 Tipo de documento: Article
Texto completo: 1 Índice: LILACS Assunto principal: Literatura de Revisão como Assunto / Glaucoma de Ângulo Fechado / Bases de Dados Bibliográficas / Tomografia de Coerência Óptica Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: Es Revista: Rev. cuba. oftalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2017 Tipo de documento: Article