Your browser doesn't support javascript.
loading
Intra and inter-rater reliability of ultrasonographic evaluation of longus colli muscle in women with migraine / Confiabilidade intra e interexaminadores da avaliação ultrassonográfica do músculo longo do pescoço em mulheres com migrânea
Almeida, Camila Carolinne Silva de; Maia, Thaís Ferreira Lopes Diniz; Wanderley, Débora; Siqueira, Gisela Rocha de; Lima, Claudia Regina Oliveira de Paiva; Raposo, Maria Cristina Falcão; Costa Neto, Joaquim José de Souza; Oliveira, Daniella Araújo de.
  • Almeida, Camila Carolinne Silva de; MD student, Postgraduate Program in Physical Therapy, Universidade Federal de Pernambuco, Recife/PE, Brazil. Recife/PE. BR
  • Maia, Thaís Ferreira Lopes Diniz; MD student, Postgraduate Program in Physical Therapy, Universidade Federal de Pernambuco, Recife/PE, Brazil. BR
  • Wanderley, Débora; MD, Postgraduate Program in Physical Therapy, Universidade Federal de Pernambuco, Recife/PE, Brazil. Recife/PE. BR
  • Siqueira, Gisela Rocha de; PhD, Mother and Child Health at Instituto de Medicina Integral Professor Fernando Figueira (IMIP), Universidade Federal de Pernambuco, Recife/PE, Brazil. Recife/PE. BR
  • Lima, Claudia Regina Oliveira de Paiva; PhD, Statisitics, Universidade de São Paulo, São Paulo/SP, Brazil. São Paulo. BR
  • Raposo, Maria Cristina Falcão; PhD, Economy, Universidde Federal de Pernambuco, Recife/PE, Brazil. Recife/PE. BR
  • Costa Neto, Joaquim José de Souza; PhD, Neuropsychiatry and Behavioral Science, Universidade Federal de Pernambuco, Recife/PE, Brazil. Recife/PE. BR
  • Oliveira, Daniella Araújo de; PhD, Neuropsychiatry and Behavioral Science, Universidade Federal de Pernambuco, Recife/PE, Brazil. Recife/PE. BR
Fisioter. Bras ; 18(3): f: 313-I: 319, 2017000.
Artigo em Português | LILACS | ID: biblio-905788
RESUMO
Objetivo: Determinar a confiabilidade intra e interexaminadores das medidas ultrassonográficas do músculo longo do pescoço em mulheres com e sem migrânea. Métodos: Trata-se de um estudo transversal, avaliando 20 mulheres com idade entre 20 e 24 anos (22 ± 2). Foram realizadas duas avaliações ultrassonográficas da área de secção transversa (cm2) do músculo longo do pescoço, em repouso e em contração com intervalo de uma semana entre elas, por dois examinadores cegos. Para análise estatística, foram utilizados o coeficiente de correlação intraclasse (ICC) e os limites de concordância. Resultados: A confiabilidade intraexaminador do grupo com migrânea, em repouso e contração, foi excelente à direita e moderada à esquerda; no grupo sem migrânea variou de excelente (0,93) no repouso, à pobre (0,35) na contração. A confiabilidade interexaminadores foi excelente (ICC > 0,75) à direita e à esquerda, no repouso, em ambos os grupos. Na contração, variou de moderada (ICC = 0,71), no lado esquerdo no grupo sem migrânea, à excelente (ICC > 0,75) nas demais mensurações. Foram observados baixos limites de concordância dos intervalos de confiança em todas as medidas. Conclusão: Foram observados baixos limites de concordância, de acordo com o intervalo de confiança, na confiabilidade das medidas ultrassonográficas do músculo longo do pescoço em mulheres com migrânea. (AU)
ABSTRACT
Objective: To determine intra and inter-rater reliability of ultrasonographic measures of the longus colli muscle in women with and without migraine. Methods: This is a cross-sectional study involving 20 women aged between 20 and 24 years (22 ± 2). Two ultrasonographic assessments, conducted one week apart by two blind examiners, were made of the crosssectional area (cm2) of the longus colli muscle, at rest and in contraction. Statistical analysis used the intraclass correlation coefficient (ICC) and limits of agreement. Results: Intra-rater reliability in the group with migraine, at rest and in contraction, was excellent on the right and moderate on the left; in the group without migraine it ranged from excellent (0.93) at rest to poor (0.35) in contraction. Inter-rater reliability was excellent (ICC > 0.75) at rest on the right and left, in both groups. In contraction, it ranged from moderate (ICC = 0.71) on the left in the group without migraine to excellent (ICC > 0.75) in the other measurements. Low limits of agreement were observed for the confidence intervals in all the measures. Conclusion: According to the confidence interval, low limits of agreement were observed, regarding the reliability of ultrasonographic measures of the longus colli muscle in women with migraine.(AU)
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Transtornos de Enxaqueca Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo de prevalência Limite: Adulto / Feminino / Humanos Idioma: Português Revista: Fisioter. Bras Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: PE, Brazil+BR / PE, Brazil+BR / PE, Brazil+BR / PE, Brazil+BR / PE, Brazil+BR / SP, Brazil+BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Transtornos de Enxaqueca Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo de prevalência Limite: Adulto / Feminino / Humanos Idioma: Português Revista: Fisioter. Bras Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: PE, Brazil+BR / PE, Brazil+BR / PE, Brazil+BR / PE, Brazil+BR / PE, Brazil+BR / SP, Brazil+BR