Your browser doesn't support javascript.
loading
Resistência à flexão de cimentos de ionômero de vidro utilizados em tratamento restaurador atraumático com alteração na proporção pó/líquido / Flexural strength of glass ionomer cements used in atraumatic restorative treatment with change in powder / liquid ratio
ROBRAC ; 26(79): 57-61, out./dez. 2017. tab
Artigo em Português | LILACS | ID: biblio-906013
RESUMO

Objetivo:

Avaliar se a alteração na proporção /líquido de cimento de ionômero de vidro nacional indicado para ART (Vitro Molar), proporciona melhorias na resistência à flexão comparando-o ao cimento importado, Fuji IX, considerado atualmente o padrão ouro no mercado. Material e

método:

Foram confeccionados 30 corpos de prova, divididos igualmente entre três grupos (G1 = Vitro Molar, manipulado conforme orientação do fabricante com proporção /líquido (1/1); G2 = Vitro Molar com proporção /líquido aumentada em 50 % (1,5/1) e G3 = Fuji IX, manipulado conforme orientação do fabricante. Os corpos de prova foram submetidos ao ensaio mecânico de resistência à flexão de três pontos (ISO 9917-2). Uma força foi aplicada no centro até a ruptura dos corpos-de-prova. Os dados foram submetidos à análise de variância e ao teste de Tukey, com nível de significância de 95%.

Resultado:

Os resultados médios obtidos para força máxima, em MPa, foram G1 3,57; G2 4,54 e G3 6,32. Houve diferença estatística entre os grupos G1 e G3. O grupo G2 apresentou semelhança estatística quando comparado aos demais grupos.

Conclusão:

O Vitro Molar com proporção /líquido alterada não apresentou diferença estatisticamente significante quando comparado aos demais grupos. O cimento Fuji IX apresentou valor estatisticamente maior de resistência à flexão que o cimento Vitro Molar manipulado na proporção recomendada pelo fabricante.
ABSTRACT

Objective:

To evaluate whether the change in the proportion powder / liquid of national glass ionomer cement formulated for ART (Vitro Molar) provides improvement in flexural strength, approaching the characteristics of the imported cement (Fuji IX). Materials and

Methods:

30 specimens were made, divided between three groups (G1 = Vitro Molar with powder / liquid ratio according to manufacturer's directions (1/1), G2 = with Vitro Molar ratio powder / liquid raised to 50%(1,5/1) and G3 = Fuji IX as manufacturer's guidelines), being subjected to mechanical testing flexural strength of three points (ISO 9917-2). A load was applied at the center until the specimens break. The data were submitted to ANOVA and Tukey's test with 95% significance level.

Result:

The average results obtained for maximum strength were G1 3.57; G2 G3 and 4.54 6.32. There was statistical difference between G1 and G3. The G2 group had statistically similar results when compared to other groups.

Conclusion:

Vitro Molar with raised powder / liquid ratio did not present a statistically significant difference when compared to the other groups. The Fuji IX cement presented a statistically higher value of flexural strength than the Vitro Molar cement manipulated in the ratio recommended by the manufacturer.

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Português Revista: ROBRAC Assunto da revista: Odontologia Ano de publicação: 2017 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Português Revista: ROBRAC Assunto da revista: Odontologia Ano de publicação: 2017 Tipo de documento: Artigo