Your browser doesn't support javascript.
loading
Forças de contração de polimerização em resinas compostas constituídas com novas matrizes orgânicas e fotoativadas por diferentes técnicas / Polymerization shrinkage stress of composite resins containing new organic matrices and photocured by different techniques
ROBRAC ; 26(79): 21-25, out./dez. 2017. ilus
Artigo em Português | LILACS | ID: biblio-906023
RESUMO
Objetivo: Verificar a força de contração de polimerização de três diferentes resinas compostas em função de dois métodos de fotopolimerização (convencional e pulso tardio). Foram selecionados para o estudo três materiais, com diferentes matrizes orgânicas: Bis-GMA ­ Filtek Z250 XT (3M-ESPE, Saint Paul, Minnesotta, EUA); Silorano ­ Filtek P90 (3M-ESPE, Saint Paul, Minnesotta, EUA) e TCD-Uretano - Charisma Diamond (Heraeus Kulzer, São Paulo, São Paulo, Brasil). Material e Método: Os corpos de prova foram confeccionados a partir de uma matriz retangular de aço inoxidável (6mm x 1mm x 2mm), posicionados em uma máquina de ensaios universal (Instron, Modelo 5965) para registro da força de contração de polimerização (Newtons). A fotoativação foi executada em cada grupo com fonte de luz do tipo LED (600mW/cm2) sob dois protocolos de fotoativação: contínuo - 40s (600mW/cm2) e pulso tardio - 5s (600mW/cm2) + 1 min sem luz + 35s (600mW/ cm2). Considerou-se como força de contração o valor registrado pela máquina de ensaios 2 minutos após o início da aplicação da luz no espécime. Os valores obtidos foram submetidos à análise de variância (ANOVA), seguido pelo teste de Tukey (p=0,05). Resultados: Não houve diferença estatística significativa entre as duas técnicas de polimerização testadas nas resinas compostas à base de silorano e TCD-Uretano, porém, houve diferença para a resina à base de Bis-GMA. Conclusão: A técnica de pulso influenciou positivamente na redução da força de contração em matriz polimérica à base de Bis-GMA, entretanto, não promoveu benefícios para as resinas à base de silorano e TCD-Uretano. PALAVRAS-CHAVE: Contração; Fotopolimerização
ABSTRACT
Purpose: To evaluate the polymerization shrinkage stress of three different composite resins cured with two methods photopolymerization (conventional and pulse delay). Three materials were selected for the study, with different organic matrices: Bis- GMA - Filtek Z250 XT (3M-ESPE, Saint Paul, Minenesotta, USA); Silorano - Filtek P90 (3M-ESPE, Saint Paul, Minenesotta, USA) e TCD-Uretane - Charisma Diamond (Heraeus Kulzer, São Paulo, São Paulo, Brazil). Materials and Method: The samples were made from a stainless steel matrix with rectangular internal geometry (6mm x 1mm x 2mm), which was mounted in an universal testing machine (Instron, Model 5965) in order to register the polymerization shrinkage stress (Newtons). The photoactivation was performed in each group with a LED (600mW/cm) light source, under two photoactivation protocols: continuous - 40s (600mW/cm) and pulse delay - 5s (600mW/cm) + 1 min with no light + 35s (600mW/cm). It was considered as shrinkage stress the value registered by the testing machine two minutes after the start of the specimen's cure. The values obtained were subjected to Analysis of Variance (ANOVA), followed by the Tukey test (p=0.05). Results: There was no significant statistical difference between the two polymerization techniques tested in the composite resins based on silorane and TCD-Urethane, but there was difference in the resin based on Bis-GMA. Conclusion: The pulse delay technique positively influenced in reducing the shrinkage stress in the polymeric matrix made of Bis- GMA, but did not provide benefits to resins made of silorane and TCD-Urethane.

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Português Revista: ROBRAC Assunto da revista: Odontologia Ano de publicação: 2017 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Português Revista: ROBRAC Assunto da revista: Odontologia Ano de publicação: 2017 Tipo de documento: Artigo