RESUMEN
Objetivo: Establecer si el implante de anillos 355° de arco (KeraRing) con técnica láser femtosegundo mejora la agudeza visual y regulariza la curvatura corneal de los pacientes con diagnóstico de queratocono central. Metodología: Estudio observacional descriptivo serie de casos. Se recolectaron datos de las historias clínicas comprendidas entre enero del 2013 y enero del 2014 de pacientes con defecto refractivo asociado a queratocono central, que fueron llevados a implante de anillos intracorneales 355° de arco mediante técnica laser femtosegundo. Resultados: El estudio incluyo 36 ojos de 32 pacientes con diagnóstico de queratocono central y edad media de 30,33 años (D.E.±10,32). La agudeza visual sin corrección, el equivalente esférico y los valores keratométricos mejoraron con respecto al valor preoperatorio y fueron estadísticamente significativos. Los valores de error refractivo esférico y cilindro mostraron una reducción media posoperatoria al año de 5,3 y 1,2 dioptrías respectivamente, pero no fueron significativas. El valor Q también mostro una mejoría de la prolaticidad pero no fue estadísticamente significativo. Conclusiones: El implante de anillos 355ª de arco (KeraRing) usando laser femtosegundo es una buena alternativa de manejo para pacientes con queratocono. Es un nuevo tipo de segmento y es importante seguir las recomendaciones de la casa productora y las mencionadas en este artículo.
ABSTRACT
Objectives: To stablish whether the implantation of an intrastromal ring segment of 355° arc (KeraRing) through a femtosecond assisted tunnel, improves visual acuity and corneal curvature patients with central keratoconus. Methods: This is a case series study of patients undergoing the procedure between January 2013 and January 2014. Results: This study included 36 eyes of 32 patients diagnosed with central keratoconus and a median age of 30,33 years. Uncorrected visual acuity, spherical equivalent and keratometry values improved and were statistically signifi cant. The Q value showed an improvement in prolaticity and the postoperative spherical refractive error and cylinder values showed a reduction of 5.3D and 1.2D respectively after 1 year without being statistically signifi cant. Conclusion: The implantation of an intrastromal corneal ring segment of 355o arc is a good alternative in the management of keratoconus patients. It is a new type of segment and the recommendations given by the manufacturers and those described in this article should be considered.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Ceratocone Tipo de estudo: Guia de Prática Clínica / Estudo observacional Idioma: Espanhol Revista: Rev. Soc. Colomb. Oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Fundación Universitaria Sanitas/CO

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Ceratocone Tipo de estudo: Guia de Prática Clínica / Estudo observacional Idioma: Espanhol Revista: Rev. Soc. Colomb. Oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Fundación Universitaria Sanitas/CO