Transformada wavelet na análise do efeito da terapia LED sobre a atividade do músculo masseter em mulheres com disfunção temporomandibular / Wavelet transformed in the analysis of LED therapy effect on the activity of masseter muscles in women with temporomandibular disorder
Sci. med. (Porto Alegre, Online)
; 28(2): ID29045, abr-jun 2018.
Article
em Pt
| LILACS
| ID: biblio-909644
Biblioteca responsável:
BR1323.1
RESUMO
OBJETIVOS:
Apresentar a transformada wavelet como uma ferramenta alternativa para o processamento dos sinais oriundos da eletromiografia quando utilizada na avaliação da atividade elétrica do músculo masseter de mulheres com disfunção temporomandibular.MÉTODOS:
Cinco voluntárias com disfunção temporomandibular passaram por quatro sessões de terapia com diodo emissor de luz (LED, light emitting diode). A eletromiografia do músculo masseter foi realizada bilateralmente antes e após o tratamento, empregando um eletromiógrafo de dois canais. Na análise dos sinais eletromiográficos foi empregada a transformada wavelet na função Morlet.RESULTADOS:
Nos escalogramas, observou-se a diminuição da ativação das fibras de alta frequência no protocolo de repouso e seu aumento no protocolo de movimento isométrico. Na análise baseada no sistema de cores RGB, foi possível observar que no protocolo de repouso do músculo masseter direito houve redução dos momentos de máxima intensidades de energia em 82% para frequências de 256-512Hz e em 42% para frequências acima de 512Hz. No músculo masseter esquerdo a redução foi de 42% na banda de frequências de 256-512Hz.CONCLUSÕES:
A análise pela transformada wavelet permitiu identificar fatores fisiológicos relacionados não somente à ativação do músculo masseter, mas também à intensidade e à relação tempo/frequência, assim como os principais tipos de fibras ativadas durante os protocolos antes e após a terapia LED em pacientes com disfunção temporomandibularABSTRACT
AIMS:
To present the wavelet transform as an alternative tool in the evaluation of the masseter muscle electrical activity in women with temporomandibular disorder after therapy with Light Emitting Diode (LED).METHODS:
Five volunteers with temporomandibular disorder underwent four sessions of LED therapy. Electromyography of the masseter muscle was performed bilaterally before and after treatment. For analysing the electromyographic signals, the wavelet transform was applied in the Morlet function.RESULTS:
In the scalogram, a decrease in the activation of the high-frequency fibers in the rest protocol and its increase in the isometric movement protocol were observed. In the analysis based on the RGB color system, we observed that in the right masseter muscle resting protocol, the moments of maximum energy intensities were reduced by 82% for frequencies of 256-512Hz and by 42% for frequencies above 512Hz. In the left masseter muscle the reduction was 42% in the frequency band of 256-512Hz.CONCLUSIONS:
Analysis by the wavelet transform allowed identification of physiological factors related not only to the activation of the masseter muscle, but also to the intensity and time / frequency relationship, as well as the main types of fibers activated during the protocols before and after LED therapy in patients with dysfunction temporomandibular.Palavras-chave
Texto completo:
1
Índice:
LILACS
Assunto principal:
Síndrome da Disfunção da Articulação Temporomandibular
/
Terapia com Luz de Baixa Intensidade
/
Eletromiografia
Tipo de estudo:
Guideline
/
Prognostic_studies
Idioma:
Pt
Revista:
Sci. med. (Porto Alegre, Online)
Assunto da revista:
Medicina
Ano de publicação:
2018
Tipo de documento:
Article