Your browser doesn't support javascript.
loading
Comparación en la medición de presión intraocular con los tonómetros de Goldmann, Pascal® y ORA (Ocular Response Analyzer) / Intraocular pressure measurement with Goldmann, Pascal and ORA tonometers
Gil, Magda; Marroquín, Guillermo; Guzmán, María del Rosario; Coy Villamil, Helena; Rodríguez, María Fernanda.
  • Gil, Magda; Hospital San José. Fundación Universitaria de Ciencias de la Salud. Bogotá. CO
  • Marroquín, Guillermo; HORUS Grupo Oftalmológico. Bogotá. CO
  • Guzmán, María del Rosario; Hospital San José. Fundación Universitaria de Ciencias de la Salud. Bogotá. CO
  • Coy Villamil, Helena; Fundación Universitaria de Ciencias de la Salud. Hospital de San José. Bogotá. CO
  • Rodríguez, María Fernanda; Fundación Universitaria de Ciencias de la Salud. Hospital de San José. Bogotá. CO
Rev. Soc. Colomb. Oftalmol ; 48(4): 300-311, 2015. ilus. tab. graf.
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-913385
RESUMEN
Introducción: el glaucoma es la principal causa de ceguera irreversible en el mundo, siendo la presión intraocular alta el factor de riesgo más importante para desarrollarlo, por eso la importancia de realizar una adecuada medición de la presión intraocular (PIO) durante el examen oftalmológico. Objetivo: evaluar la concordancia de la medida de la presión intraocular tomada con los tonómetros de Goldmann, Pascal® y ORA, en pacientes con glaucoma de la consulta externa del servicio de oftalmología del Hospital de San José. Diseño: estudio descriptivo, de corte transversal y concordancia. Métodos: se compararon las medidas de Goldmann corregido, Pascal® y ORA corregido en 90 pacientes (167 ojos) con diagnóstico de glaucoma que asisten a consulta de oftalmología del Hospital de San José. Resultados: el coeficiente de correlación y concordancia de Lin entre Goldmann corregido y Pascal® es de 0.61; entre Goldmann corregido y ORA corregido de 0.64 y entre Pascal® y ORA corregido de 0.81. Conclusiones: se encontró una concordancia moderada para los tres tonómetros en la medición de la PIO en los ojos con glaucoma del servicio de oftalmología del Hospital de San José. Los tres métodos no son reemplazables, por lo tanto el seguimiento de los pacientes siempre debe ser tomado con un mismo método.
ABSTRACT
Introduction: glaucoma is the leading cause of worldwide irreversible blindness, high intraocular pressure remains the most important risk factor; because of that, it is essential to measure accurately the intraocular pressure (IOP). Objective: to evaluate the intraocular pressure correspondence of Goldmann-correlated IOP, Pascal® dynamic contour tonometer and Reichert Ocular Response Analyzer ORA tonometers in patients with glaucoma diagnosis at Ophthalmology Service, Hospital de San José. Design: a descriptive, cross-sectional and matching. Methods: measurements of Goldmann correlated IOP, Pascal® and ORA corneal compensated IOP were compared, in patients (167 eyes) diagnosed with glaucoma attending at ophthalmology Hospital San José. Results: the correlation coeffi cient and concordance Lin between Goldmann correlated IOP and Pascal® is 0.61; between ORA and Goldmann correlated IOP is 0.64 and between Pascal® and ORA is 0.81. Conclusions: we found a moderate agreement for the three tonometers for measuring IOP in eyes glaucoma attending at ophthalmology Hospital San José. The three methods are not replaceable, therefore monitoring of patients should always be taken with the same method.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Pressão Intraocular Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo de prevalência / Fatores de risco Idioma: Espanhol Revista: Rev. Soc. Colomb. Oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Fundación Universitaria de Ciencias de la Salud/CO / HORUS Grupo Oftalmológico/CO / Hospital San José/CO

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Pressão Intraocular Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo de prevalência / Fatores de risco Idioma: Espanhol Revista: Rev. Soc. Colomb. Oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Fundación Universitaria de Ciencias de la Salud/CO / HORUS Grupo Oftalmológico/CO / Hospital San José/CO