Paper-Based Microfluidics Immunoassay for Detection of Canine Distemper Virus
Mazzu-Nascimento, Thiago; Donofrio, Fabiana Cristina; Bianchi, Beatriz Cutilak; Travensolo, Regiane de Fátima; Souza Junior, João Batista; Moraes, Daniel Angeli; Morbioli, Giorgio Gianini; Segato, Thiago Pinotti; Varanda, Laudemir Carlos; Carrilho, Emanuel.
  • Mazzu-Nascimento, Thiago; Universidade de São Paulo. Instituto de Química de São Carlos. São Carlos. BR
  • Donofrio, Fabiana Cristina; Universidade Federal de Mato Grosso. Instituto de Ciências da Saúde. Sinop. BR
  • Bianchi, Beatriz Cutilak; Partecurae Pesquisa e Desenvolvimento. São Carlos. BR
  • Travensolo, Regiane de Fátima; Partecurae Pesquisa e Desenvolvimento. São Carlos. BR
  • Souza Junior, João Batista; Universidade de São Paulo. Instituto de Química de São Carlos. São Carlos. BR
  • Moraes, Daniel Angeli; Universidade de São Paulo. Instituto de Química de São Carlos. São Carlos. BR
  • Morbioli, Giorgio Gianini; Universidade de São Paulo. Instituto de Química de São Carlos. São Carlos. BR
  • Segato, Thiago Pinotti; Partecurae Pesquisa e Desenvolvimento. São Carlos. BR
  • Varanda, Laudemir Carlos; Universidade de São Paulo. Instituto de Química de São Carlos. São Carlos. BR
  • Carrilho, Emanuel; Universidade de São Paulo. Instituto de Química de São Carlos. São Carlos. BR
Braz. arch. biol. technol ; 60: e17160317, 2017. graf
Artigo em Inglês | LILACS | ID: biblio-951459
ABSTRACT
ABSTRACT Paper-based devices present low-cost and are versatile, making them very attractive for clinical analysis. To manufacture those devices wax patterns are printed on paper surface and upon heating the wax permeates through the entire thickness of the paper, creating hydrophobic barriers that delimit test areas. Antibodies produced in rabbits against canine distemper virus (CDV) were physically adsorbed on the surface of gold nanoparticles (AuNPs) and incubated with CDV viral antigens, forming the immunocomplex. Anti-CDV antibodies were immobilized into the microchannels by physical adsorption, forming the test region. The test solution containing conjugated AuNPs was applied at the bottom of the microchannel and it was eluted with a phosphate buffer solution 0.01 M pH 7.4. When the solution containing the AuNPs reached the test zone the recognition of antigens contained on the immunocomplex occurred with the consequent development of a red line, which represents a positive outcome for the test. This method demonstrated the success of physical immobilization of antibodies on AuNPs and the physical immobilization of antibodies on cellulose's surface. This colorimetric assay brings simplicity and versatility to clinical analyses, presenting potential for CDV diagnosis.


Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Estudo diagnóstico Idioma: Inglês Revista: Braz. arch. biol. technol Assunto da revista: Biologia Ano de publicação: 2017 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Partecurae Pesquisa e Desenvolvimento/BR / Universidade Federal de Mato Grosso/BR / Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Estudo diagnóstico Idioma: Inglês Revista: Braz. arch. biol. technol Assunto da revista: Biologia Ano de publicação: 2017 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Partecurae Pesquisa e Desenvolvimento/BR / Universidade Federal de Mato Grosso/BR / Universidade de São Paulo/BR