Your browser doesn't support javascript.
loading
Evaluation of deflection forces of orthodontic wires with different ligation types
Henriques, José Fernando Castanha; Higa, Rodrigo Hitoshi; Semenara, Nayara Thiago; Janson, Guilherme; Fernandes, Thais Maria Freire; Sathler, Renata.
  • Henriques, José Fernando Castanha; Universidade de São Paulo. Bauru Dental School. Department of Orthodontics. Bauru. BR
  • Higa, Rodrigo Hitoshi; Universidade de São Paulo. Bauru Dental School. Department of Orthodontics. Bauru. BR
  • Semenara, Nayara Thiago; Universidade de São Paulo. Bauru Dental School. Department of Orthodontics. Bauru. BR
  • Janson, Guilherme; Universidade de São Paulo. Bauru Dental School. Department of Orthodontics. Bauru. BR
  • Fernandes, Thais Maria Freire; Universidade Norte do Paraná. Department of Orthodontics. Londrina. BR
  • Sathler, Renata; Universidade de São Paulo. Hospital for Rehabilitation of Craniofacial Anomalies. Bauru. BR
Braz. oral res. (Online) ; 31: e49, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-952103
ABSTRACT
Abstract The aim of this study was to evaluate deflection forces of orthodontic wires of different alloys engaged into conventional brackets using several ligation types. Stainless steel, conventional superelastic nickel-titanium and thermally activated nickel-titanium archwires tied into conventional brackets by a ring-shaped elastomeric ligature (RSEL), a 8-shaped elastomeric ligature (8SEL) and a metal ligature (ML) were tested. A clinical simulation device was created especially for this study and forces were measured with an Instron Universal Testing Machine. For the testing procedure, the block representing the maxillary right central incisor was moved 0.5 and 1 mm bucco-lingually at a constant speed of 2 mm/min, and the forces released by the wires were recorded, in accordance with the ISO 15841 guidelines. In general, the RSEL showed lighter forces, while 8SEL and ML showed higher values. At the 0.5 mm deflection, the 8SEL presented the greatest force, but at the 1.0 mm deflection the ML had a statistically similar force. Based on our evaluations, to obtain lighter forces, the thermally activated nickel-titanium wire with the RSEL are recommended, while the steel wire with the 8SEL or the ML are recommended when larger forces are desired. The ML exhibited the highest force increase with increased deflections, compared with the elastomeric ligatures.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Fios Ortodônticos / Braquetes Ortodônticos / Desenho de Aparelho Ortodôntico Tipo de estudo: Estudos de avaliação / Guia de Prática Clínica Idioma: Inglês Revista: Braz. oral res. (Online) Assunto da revista: Odontologia Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Norte do Paraná/BR / Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Fios Ortodônticos / Braquetes Ortodônticos / Desenho de Aparelho Ortodôntico Tipo de estudo: Estudos de avaliação / Guia de Prática Clínica Idioma: Inglês Revista: Braz. oral res. (Online) Assunto da revista: Odontologia Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Norte do Paraná/BR / Universidade de São Paulo/BR