Your browser doesn't support javascript.
loading
Percutaneous lead extraction in infection of cardiac implantable electronic devices: a systematic review
Menezes Júnior, Antônio da Silva; Magalhães, Thaís Rodrigues; Morais, Alana de Oliveira Alarcão.
  • Menezes Júnior, Antônio da Silva; Pontifícia Universidade Católica de Goiás. Escola de Ciências Médicas, Farmacêuticas e Biomédicas. Goiânia. BR
  • Magalhães, Thaís Rodrigues; Pontifícia Universidade Católica de Goiás. Escola de Ciências Médicas, Farmacêuticas e Biomédicas. Goiânia. BR
  • Morais, Alana de Oliveira Alarcão; Pontifícia Universidade Católica de Goiás. Escola de Ciências Médicas, Farmacêuticas e Biomédicas. Goiânia. BR
Rev. bras. cir. cardiovasc ; 33(2): 194-202, Mar.-Apr. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-958399
ABSTRACT
Abstract Introduction: In the last two decades, the increased number of implants of cardiac implantable electronic devices has been accompanied by an increase in complications, especially infection. Current recommendations for the appropriate treatment of cardiac implantable electronic devices-related infections consist of prolonged antibiotic therapy associated with complete device extraction. The purpose of this study was to analyze the importance of percutaneous extraction in the treatment of these devices infections. Methods: A systematic review search was performed in the PubMed, BVS, Cochrane CENTRAL, CAPES, SciELO and ScienceDirect databases. A total of 1,717 studies were identified and subsequently selected according to the eligibility criteria defined by relevance tests by two authors working independently. Results: Sixteen studies, describing a total of 3,354 patients, were selected. Percutaneous extraction was performed in 3,081 patients. The average success rate for the complete percutaneous removal of infected devices was 92.4%. Regarding the procedure, the incidence of major complications was 2.9%, and the incidence of minor complications was 8.4%. The average in-hospital mortality of the patients was 5.4%, and the mortality related to the procedure ranged from 0.4 to 3.6%. The mean mortality was 20% after 6 months and 14% after a one-year follow-up. Conclusion: Percutaneous extraction is the main technique for the removal of infected cardiac implantable electronic devices, and it presents low rates of complications and mortality related to the procedure.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Marca-Passo Artificial / Infecções Relacionadas à Prótese / Desfibriladores Implantáveis / Remoção de Dispositivo Tipo de estudo: Estudo de etiologia / Guia de Prática Clínica / Estudo prognóstico / Fatores de risco / Revisões Sistemáticas Avaliadas Limite: Humanos Idioma: Inglês Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2018 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Pontifícia Universidade Católica de Goiás/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Marca-Passo Artificial / Infecções Relacionadas à Prótese / Desfibriladores Implantáveis / Remoção de Dispositivo Tipo de estudo: Estudo de etiologia / Guia de Prática Clínica / Estudo prognóstico / Fatores de risco / Revisões Sistemáticas Avaliadas Limite: Humanos Idioma: Inglês Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2018 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Pontifícia Universidade Católica de Goiás/BR