Your browser doesn't support javascript.
loading
Evaluación teórica del desempeño del electrodo, modificado por el oxihidróxido de cobalto (III) en la detección del ácido úrico / Theoretical evaluation of the work of the electrode, modified by cobalt (III) oxyhydroxide, in the uric acid detection
Tkach, Volodymyr V.; Ivanushko, Yana G.; Lukanova, Svitlana M.; Kushnir, Marta V.; de Oliveira, Sílvio C.; Ojani, Reza; Luganska, Olga V.; Yagodynets', Petró I..
  • Tkach, Volodymyr V.; Universidad Nacional de Chernivtsi. Chernivtsi. UA
  • Ivanushko, Yana G.; Universidad Nacional de Chernivtsi. Chernivtsi. UA
  • Lukanova, Svitlana M.; Universidad Nacional de Chernivtsi. Chernivtsi. UA
  • Kushnir, Marta V.; Universidad Nacional de Chernivtsi. Chernivtsi. UA
  • de Oliveira, Sílvio C.; Universidade Federal de Mato Grosso do Sul. Campo Grande. BR
  • Ojani, Reza; Universidad de Mazandarán. Babolsar. IR
  • Luganska, Olga V.; Universidad Nacional de Zaporizhzhya. Facultad de Biología. Zaporizhzhya. UA
  • Yagodynets', Petró I.; Universidad Nacional de Chernivtsi. Chernivtsi. UA
Rev. colomb. ciencias quim. farm ; 47(2): 289-300, maio-ago. 2018.
Artigo em Espanhol | LILACS | ID: biblio-978273
RESUMEN
RESUMEN La posibilidad del empleo de oxihidróxido de cobalto como modificador del electrodo en la detección del ácido úrico se investigó desde el punto de vista teórico. Se sugiere el mecanismo del desempeño del compuesto inorgánico en el proceso, y el modelo, correspondiente al proceso, se analizó mediante la teoría de estabilidad lineal y análisis de bifurcaciones. Se concluye que el oxihidróxido de cobalto puede servir como un modificador eficiente, facilitando la oxidación del analito en medio neutro en el modo galvanostático. La inestabilidad monotónica para este caso no puede realizarse, y la oscilatoria es causada por el único factor.
ABSTRACT
SUMMARY The possibility of use of cobalt oxyhydroxide as an electrode modifier in the uric acid determination has been investigated from the theoretical point of view. The mechanism of the use of the inorganic compound in the process has been suggested, and the model, correspondent to the process, has been analyzed by means of linear stability theory and bifurcation analysis. It has been concluded that the cobalt oxyhydroxide may serve as an efficient modifier, making easier the analyte oxidation in neutral media in galvanostatic mode. The monotonic instability for this case isn't capable to realize, and the oscillatory behavior is caused by the unique factor.


Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Idioma: Espanhol Revista: Rev. colomb. ciencias quim. farm Assunto da revista: Farmácia / Química Ano de publicação: 2018 Tipo de documento: Artigo País de afiliação: Brasil / Irã / Ucrânia Instituição/País de afiliação: Universidad Nacional de Chernivtsi/UA / Universidad Nacional de Zaporizhzhya/UA / Universidad de Mazandarán/IR / Universidade Federal de Mato Grosso do Sul/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Idioma: Espanhol Revista: Rev. colomb. ciencias quim. farm Assunto da revista: Farmácia / Química Ano de publicação: 2018 Tipo de documento: Artigo País de afiliação: Brasil / Irã / Ucrânia Instituição/País de afiliação: Universidad Nacional de Chernivtsi/UA / Universidad Nacional de Zaporizhzhya/UA / Universidad de Mazandarán/IR / Universidade Federal de Mato Grosso do Sul/BR