Análisis diferencial de instrumentos ultrasonicos vs instrumentos rotatorios en osteotomía, empleando modelos animales in vivo / Differential anlysis of ultrasonic vs. rotating instruments in osteotomy, using in vivo animal models
Zanabria, Jesús; Paredes, Wilbert; Pacompía, Karla; Franco, Fredy.
  • Zanabria, Jesús; Centro Especializado en Ciencias Odontológicas. Puno. PE
  • Paredes, Wilbert; Centro Especializado en Ciencias Odontológicas. Puno. PE
  • Pacompía, Karla; Centro Especializado en Ciencias Odontológicas. Puno. PE
  • Franco, Fredy; Centro Especializado en Ciencias Odontológicas. Puno. PE
Evid. odontol. clín ; 2(2): 19-24, jul.-dic. 2016. ilus., tabs., grafs.
Artigo em Espanhol | LILACS | ID: biblio-999989
RESUMEN
Objetivos: El presente estudio se realizó con el objetivo de demostrar que la adaptación de los insertos de un equipo de piezocirugía a un equipo de ultrasonido convencional, es una alternativa viable para la ultiización en las cirugía que incluyan secciones óseas, porque se logra conservar los principios sobre los que se basa la utilización de la piezo cirugía. Utilizando un estudio comparativo entre dos tecnologías distintas como son: el empleo de instrumentos adaptados a un ultrasonido convencional y el empleo de instrumentos rotacionales; pretendemos contrastar los beneficios quirúrgicos, clínicos e histológicos que ofrecen ambas tecnologías. Método: Para el desarrollo de este estudio se optó por seleccionar 06 animales experimentales, a los cuales se les practicaron osteotomías en sus respectivas calotas. Estos se dividieron en dos grupos de 03 unidades. El primer grupo, fue sometido a osteotomía con instrumento rotatorio y el segundo grupo a osteotomías con insertos adaptados a un ultrasonido de uso convencional; en ambos grupos se realizó la toma de bloques óseos de sus calotas, las que fueron procesadas histológicamente para su respectivo análisis. Resultados: Se evidenció que las osteotomías realizadas con instrumentos rotatorios tuvieron cortes irregulares y gruesos, conduciendo a menor preservación de estructuras óseas; sin embargo las osteotomías elaboradas con los insertos adaptados al ultrasonido convencional, lograron evidenciar cortes finos y precisos los que repercutieron enseprrvear mayor cantidad de osteocitos, vasos sanguíneos y puntales óseos. Conclusiones: El empleo de los insertos adaptados al ultrasonido convencional, mejoran notablemente la práctica quirúrgica y la conservación de estructuras histológica cuando realizamos secciones óseas; al ser comparados con en el empleo de los instrumentos rotacionales demuestran tener cualidades superiores, asemejándose a las bondades y principios presentes en la cirugía piezo eléctrica. (AU)
ABSTRACT
Objectives: The present study is performs with the objective ofdemonstrate that the adaptation of the inserts of piezo surger y to a equipment of conventional ultrasound, is an alternative viable for use in surgeries that include sections bone, because is manages keep the principles on which is based the use of the piezo surgery. Using a comparative study between two different technologies such as: the use of instruments adapted to a conventional ultrasound and the use of rotational instruments; We intend to contrast the benefits surgical, clinical and histological that offer both technologies; the results was compared and this we allowed the choice of the technology that provide to conservative surgery and minimally invasive. Method: For the development of this study are opted by select 0 6 animal experimental, to which is les practiced osteotomies intheir respective caps. These are divided in two groups of 03 units each one. The first group, was submitted to osteotomy with instrument Rotary and the second group to osteotomies with inserts adapted to an ultrasound of use conventional; taking bone blocks of their cranial caps, which were derived to the Department of histology for their respective analysis was performed in both groups. Results: The osteotomies performed with rotating instruments were irregular and thick cuts, leading to increased cell death and less preser vation of blood vessels; however the osteotomies with adapted nserts, i to conventional ultrasound, allowed fine and precise cuts that less affected and preserve more osteocytes, bony struts and blood vessels. Conc lusions: The use of adapted inserts to conventional ultrasound, substantially improves the surgical practice and histological structures conservation when we perform bone sections; showed more superior qualities to be compared with the use of instruments rotational, resembling the benefits and principles present in the surgery piezoelectric. (AU)
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Osteotomia / Ultrassom Limite: Humanos Idioma: Espanhol Revista: Evid. odontol. clín Assunto da revista: Medicina Bucal / Odontologia Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Peru Instituição/País de afiliação: Centro Especializado en Ciencias Odontológicas/PE

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Osteotomia / Ultrassom Limite: Humanos Idioma: Espanhol Revista: Evid. odontol. clín Assunto da revista: Medicina Bucal / Odontologia Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Peru Instituição/País de afiliação: Centro Especializado en Ciencias Odontológicas/PE