Unusual treatment of pacemaker pocket infection: a case report
Journal of Tehran University Heart Center [The]. 2010; 5 (4): 202-204
em Inglês | IMEMR | ID: emr-108622
ABSTRACT
Pocket infection of a cardiac device is usually treated by removing the device and re-implanting it in a new site after complete treatment of the infection. This report illustrates a complicated case of pocket infection in the wake of the implantation of a permanent pacemaker [cardiac resynchronization therapy]. The patient was treated conservatively through daily irrigation and dressing, broad-spectrum antibiotics, and debridement without the device being removed; the generator was kept out of the pocket for 5 weeks and then re-implanted in the same location successfully. The method of treatment presented herein can be of value, not least in the elderly population who might experience life-threatening events following the replacement of their cardiac devices
Assuntos
Buscar no Google
Índice: IMEMR (Mediterrâneo Oriental) Assunto principal: Infecção da Ferida Cirúrgica / Dispositivos de Terapia de Ressincronização Cardíaca / Infecções Tipo de estudo: Relato de Casos Limite: Humanos / Masculino Idioma: Inglês Revista: J. Tehran Univ. Heart Cent. Ano de publicação: 2010