Aortic arch replacement with moderate hypothermia and a modified three-pump circuit
Journal of Tehran University Heart Center [The]. 2011; 6 (4): 211-213
em Inglês
| IMEMR
| ID: emr-146544
ABSTRACT
A strategy employing moderate hypothermia for the replacement of the aortic arch is proposed to avoid the complications of profound hypothermic circulatory arrest. Two patients underwent the complete replacement of the aortic arch using three pumps - for the brain, thoracoabdominal aorta, and heart, respectively. There were no complications and the patients were extubated uneventfully. The method preserved the auto-regulation of the cerebral blood flow without high vascular resistance
Buscar no Google
Índice:
IMEMR (Mediterrâneo Oriental)
Assunto principal:
Perfusão
/
Cirurgia Torácica
/
Encéfalo
/
Ponte Cardiopulmonar
/
Desenho de Equipamento
/
Parada Circulatória Induzida por Hipotermia Profunda
/
Hipotermia Induzida
Tipo de estudo:
Relato de Casos
Limite:
Humanos
/
Masculino
Idioma:
Inglês
Revista:
J. Tehran Univ. Heart Cent.
Ano de publicação:
2011
Similares
MEDLINE
...
LILACS
LIS