Your browser doesn't support javascript.
loading
Should a double-lumen catheter be withdrawn?
JCVTR-Journal of Cardiovascular and Thoracic Research. 2011; 3 (3): 97-99
em Inglês | IMEMR | ID: emr-160952
ABSTRACT
Haemodialysis needs a credible and recurrent access to the systemic circulation which can be accomplished by way of central vein catheterization. We report the case of bleeding after withdrawal of the double lumen catheter. A 36-year-old woman who was a known case of end-stage renal disease referred to a dialysis center because of her arteriovenous fistula malfunction. A double-lumen catheter was inserted via the right internal jugular vein but failed to become functional so in the emergency department we decided to withdrawal catheter under cardiac monitoring and pulse oximetry but unfortunately A few minutes after the withdrawal of the double lumen Catheter the patient became agitated and confused. The resuscitation team after infusing IV fluid and blood decided to emergent thoracotomy. We control bleeding by direct pressure and repaired a rupture of the posterior aspect of the right internal jugular and right subclavian vein junction. Six hours later she became alert and one week after discharged, she was in well general condition
Buscar no Google
Índice: IMEMR (Mediterrâneo Oriental) Idioma: Inglês Revista: J. Cardiovasc. Thorac. Res. Ano de publicação: 2011

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: IMEMR (Mediterrâneo Oriental) Idioma: Inglês Revista: J. Cardiovasc. Thorac. Res. Ano de publicação: 2011